new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Oct 27

CRC-Router: Risk-Constrained Routing for Medical Agentic AI Systems

Agentic AI systems are increasingly being explored in medical imaging to improve throughput and reduce clinician workload; however, safe deployment remains challenging because autonomous errors may propagate into downstream clinical decisions. A central requirement is therefore not only strong predictive performance, but also a reliable routing mechanism that determines when the system should proceed autonomously and when a case should be escalated for further review. To address this gap, we propose CRC-Router, a risk-constrained, uncertainty-aware routing module that is applicable to both conventional medical prediction models and agentic medical AI systems. CRC-Router combines multiple complementary uncertainty signals with the predictive score to construct a per-finding routing feature vector, maps this vector to an estimated wrong-accept risk using a lightweight per-finding risk model, and then applies Conformal Risk Control (CRC) to calibrate acceptance thresholds under a user-specified risk target. Instantiated on chest X-ray multi-finding triage using the NIH ChestX-ray14 dataset, CRC-Router achieves the strongest empirical risk--coverage trade-off among the evaluated baselines, both as a standalone routing layer and as a plug-in module integrated with the state-of-the-art MedRAX agent. These results demonstrate both the effectiveness of CRC-Router in selective medical automation and its modular, model-agnostic compatibility with existing predictive and agentic medical pipelines. Code is publicly available at https://github.com/XLIAaron/CRC-Router

  • 8 authors
·
Sep 24

Xplainer: From X-Ray Observations to Explainable Zero-Shot Diagnosis

Automated diagnosis prediction from medical images is a valuable resource to support clinical decision-making. However, such systems usually need to be trained on large amounts of annotated data, which often is scarce in the medical domain. Zero-shot methods address this challenge by allowing a flexible adaption to new settings with different clinical findings without relying on labeled data. Further, to integrate automated diagnosis in the clinical workflow, methods should be transparent and explainable, increasing medical professionals' trust and facilitating correctness verification. In this work, we introduce Xplainer, a novel framework for explainable zero-shot diagnosis in the clinical setting. Xplainer adapts the classification-by-description approach of contrastive vision-language models to the multi-label medical diagnosis task. Specifically, instead of directly predicting a diagnosis, we prompt the model to classify the existence of descriptive observations, which a radiologist would look for on an X-Ray scan, and use the descriptor probabilities to estimate the likelihood of a diagnosis. Our model is explainable by design, as the final diagnosis prediction is directly based on the prediction of the underlying descriptors. We evaluate Xplainer on two chest X-ray datasets, CheXpert and ChestX-ray14, and demonstrate its effectiveness in improving the performance and explainability of zero-shot diagnosis. Our results suggest that Xplainer provides a more detailed understanding of the decision-making process and can be a valuable tool for clinical diagnosis.

  • 6 authors
·
Mar 23, 2023

Agents Catching Agents: Shortcut Cascades and Benchmark Gaming in Clinical Multi-Agent Systems

Clinical decision support is moving toward committees of language-model agents deliberating on a shared workspace. We ask whether such committees can be gamed by shortcuts, cues a benchmark rewards but a clinician would ignore. Across seven cohorts on six public datasets spanning text (MedQA-USMLE, MedMCQA, MIMIC-CXR reports), imaging (NIH ChestX-ray14, MIMIC-CXR-JPG, CheXpert) and tabular ICU records (SUPPORT2), Gemini committees resist these cues in isolation (flip 5-16%), yet a socially plausible shortcut spreads: when two peers assert the same wrong answer, the holdout under test adopts it in 38% of cases, as does a false "pre-screen" system flag, on both capability tiers. Of three oversight agents, a gate cannot separate adoption from honest agreement (false-positive rate 100%); a same-lineage judge reading only the transcript flags adoption on text (precision 100%, recall 93%) but collapses onto the gate in imaging; a referee that privately re-queries the holdout transfers to imaging (77-88% precision, 13-21% false-positive rate). Tripling a cue's visual salience does not move contagion, whereas a second peer voice raises it by half again. Gaming a hidden rubric is near-silent: only 1/10 text and 1/134 imaging drifters name the rubric they moved toward. What games a committee is social plausibility, and only a referee independent of self-report catches it. Code: https://github.com/criticaldata/benchmaxxing

SwinCheX: Multi-label classification on chest X-ray images with transformers

According to the considerable growth in the avail of chest X-ray images in diagnosing various diseases, as well as gathering extensive datasets, having an automated diagnosis procedure using deep neural networks has occupied the minds of experts. Most of the available methods in computer vision use a CNN backbone to acquire high accuracy on the classification problems. Nevertheless, recent researches show that transformers, established as the de facto method in NLP, can also outperform many CNN-based models in vision. This paper proposes a multi-label classification deep model based on the Swin Transformer as the backbone to achieve state-of-the-art diagnosis classification. It leverages Multi-Layer Perceptron, also known as MLP, for the head architecture. We evaluate our model on one of the most widely-used and largest x-ray datasets called "Chest X-ray14," which comprises more than 100,000 frontal/back-view images from over 30,000 patients with 14 famous chest diseases. Our model has been tested with several number of MLP layers for the head setting, each achieves a competitive AUC score on all classes. Comprehensive experiments on Chest X-ray14 have shown that a 3-layer head attains state-of-the-art performance with an average AUC score of 0.810, compared to the former SOTA average AUC of 0.799. We propose an experimental setup for the fair benchmarking of existing methods, which could be used as a basis for the future studies. Finally, we followed up our results by confirming that the proposed method attends to the pathologically relevant areas of the chest.

  • 5 authors
·
Jun 8, 2022