new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Sep 30

Camera calibration for the surround-view system: a benchmark and dataset

Surround-view system (SVS) is widely used in the Advanced Driver Assistance System (ADAS). SVS uses four fisheye lenses to monitor real-time scenes around the vehicle. However, accurate intrinsic and extrinsic parameter estimation is required for the proper functioning of the system. At present, the intrinsic calibration can be pipeline by utilizing checkerboard algorithm, while extrinsic calibration is still immature. Therefore, we proposed a specific calibration pipeline to estimate extrinsic parameters robustly. This scheme takes a driving sequence of four cameras as input. It firstly utilizes lane line to roughly estimate each camera pose. Considering the environmental condition differences in each camera, we separately select strategies from two methods to accurately estimate the extrinsic parameters. To achieve accurate estimates for both front and rear camera, we proposed a method that mutually iterating line detection and pose estimation. As for bilateral camera, we iteratively adjust the camera pose and position by minimizing texture and edge error between ground projections of adjacent cameras. After estimating the extrinsic parameters, the surround-view image can be synthesized by homography-based transformation. The proposed pipeline can robustly estimate the four SVS camera extrinsic parameters in real driving environments. In addition, to evaluate the proposed scheme, we build a surround-view fisheye dataset, which contains 40 videos with 32,000 frames, acquired from different real traffic scenarios. All the frames in each video are manually labeled with lane annotation, with its GT extrinsic parameters. Moreover, this surround-view dataset could be used by other researchers to evaluate their performance. The dataset will be available soon.

  • 5 authors
·
Dec 27, 2023

Geometric Reliability of Neural Population Codes: Sampling Calibration and Within-Session Nonstationarity

Trial-to-trial variability limits how reliably neural population geometry can be estimated, while comparisons across populations depend on neuron and trial counts, response quality, and clustered sampling. We quantified within-session geometric reliability using Shesha, the Spearman correlation between representational dissimilarity matrices estimated from independent trial subsets, in all 39 Steinmetz Neuropixels sessions and in olfactory bulb and piriform cortex recordings from Bolding and Franks. Steinmetz analyses matched neurons and repetitions, compared observed reliability with a stationary residual-bootstrap expectation, and used mouse-level or mouse-clustered inference. Mean matched reliability was 0.0402 across 312 area-by-session recordings. Regional differences and reliability above the stationary benchmark did not survive correction. Temporal effects received the strongest support: interleaving early and late trials increased reliability relative to blocked allocation (Δ=0.02666, q=0.001953), and RDM similarity declined with within-session lag (mean mouse-level slope =-0.01912, q=0.001953; n=10 mice). Outer-cross-fitted reliability was not associated with choice-direction coupling or stimulus or response-direction decoding after correction. Olfactory comparisons remained descriptive because few paired sessions and no animal identities were available. In held-out simulations, associative recurrence outperformed feedforward subspace denoising but not divisive normalization. Representational geometry became less reproducible with temporal separation within a session, and comparisons across neural populations require sampling calibration and independent inference.

  • 1 authors
·
Sep 6 2

Assessment of a cost-effective headphone calibration procedure for soundscape evaluations

To increase the availability and adoption of the soundscape standard, a low-cost calibration procedure for reproduction of audio stimuli over headphones was proposed as part of the global ``Soundscape Attributes Translation Project'' (SATP) for validating ISO/TS~12913-2:2018 perceived affective quality (PAQ) attribute translations. A previous preliminary study revealed significant deviations from the intended equivalent continuous A-weighted sound pressure levels (L_{A,eq}) using the open-circuit voltage (OCV) calibration procedure. For a more holistic human-centric perspective, the OCV method is further investigated here in terms of psychoacoustic parameters, including relevant exceedance levels to account for temporal effects on the same 27 stimuli from the SATP. Moreover, a within-subjects experiment with 36 participants was conducted to examine the effects of OCV calibration on the PAQ attributes in ISO/TS~12913-2:2018. Bland-Altman analysis of the objective indicators revealed large biases in the OCV method across all weighted sound level and loudness indicators; and roughness indicators at 5{\%} and 10{\%} exceedance levels. Significant perceptual differences due to the OCV method were observed in about 20{\%} of the stimuli, which did not correspond clearly with the biased acoustic indicators. A cautioned interpretation of the objective and perceptual differences due to small and unpaired samples nevertheless provide grounds for further investigation.

  • 6 authors
·
Jul 24, 2022

NaviCache: Test-Time Self-Calibration Caching for Video Generation

Video Diffusion Models (VDMs) is constrained by immense computational costs. While offline calibration-based acceleration suffers from calibration data dependency, prohibitive calibration duration, and susceptibility to distribution shifts, offline calibration-free methods eliminate these hurdles. However, since they rely on instantaneous zero-order approximations where the mapping between input and output differences varies in real-time, they are susceptible to observational noise and ignore the intrinsic momentum within the diffusion trajectory. In this paper, we propose NaviCache, a plug-and-play test-time self-calibration method re-conceptualizing feature evolution as an Inertial Navigation System (INS) problem. NaviCache bridges the fundamental domain gap and the non-stationary nature of diffusion by modeling the relative coupling between input and output variations. We introduce a dual-state estimation architecture that adaptively tracks the feature change ratio and its latent drift, initialized via a specialized Initial Alignment phase. By integrating a time-dependent noise schedule with an uncertainty-aware Measurement Update mechanism, NaviCache provides a theoretically grounded mechanism for error-bounded computation skipping. Extensive experiments on the HunyuanVideo, Wan, and Open-Sora series demonstrate that NaviCache exhibits more accurate error judgment for computation skipping and achieves outstanding comprehensive performance.

  • 9 authors
·
Jul 10

Preliminary assessment of a cost-effective headphone calibration procedure for soundscape evaluations

The introduction of ISO 12913-2:2018 has provided a framework for standardized data collection and reporting procedures for soundscape practitioners. A strong emphasis was placed on the use of calibrated head and torso simulators (HATS) for binaural audio capture to obtain an accurate subjective impression and acoustic measure of the soundscape under evaluation. To auralise the binaural recordings as recorded or at set levels, the audio stimuli and the headphone setup are usually calibrated with a HATS. However, calibrated HATS are too financially prohibitive for most research teams, inevitably diminishing the availability of the soundscape standard. With the increasing availability of soundscape binaural recording datasets, and the importance of cross-cultural validation of the soundscape ISO standards, e.g.\ via the Soundscape Attributes Translation Project (SATP), it is imperative to assess the suitability of cost-effective headphone calibration methods to maximise availability without severely compromising on accuracy. Hence, this study objectively examines an open-circuit voltage (OCV) calibration method in comparison to a calibrated HATS on various soundcard and headphone combinations. Preliminary experiments found that calibration with the OCV method differed significantly from the reference binaural recordings in sound pressure levels, whereas negligible differences in levels were observed with the HATS calibration.

  • 7 authors
·
May 10, 2022

Rethinking Practical and Efficient Quantization Calibration for Vision-Language Models

Post-training quantization (PTQ) is a primary approach for deploying large language models without fine-tuning, and the quantized performance is often strongly affected by the calibration in PTQ. By contrast, in vision-language models (VLMs), substantial differences between visual and text tokens in their activation distributions and sensitivities to quantization error pose significant challenges for effective calibration during PTQ. In this work, we rethink what PTQ calibration should align with in VLMs and propose the Token-level Importance-aware Layer-wise Quantization framework (TLQ). Guided by gradient information, we design a token-level importance integration mechanism for quantization error, and use it to construct a token-level calibration set, enabling a more fine-grained calibration strategy. Furthermore, TLQ introduces a multi-GPU, quantization-exposed layer-wise calibration scheme. This scheme keeps the layer-wise calibration procedure consistent with the true quantized inference path and distributes the complex layer-wise calibration workload across multiple RTX3090 GPUs, thereby reducing reliance on the large memory of A100 GPUs. TLQ is evaluated across two models, three model scales, and two quantization settings, consistently achieving performance improvements across all settings, indicating its strong quantization stability. The code will be released publicly.

  • 7 authors
·
Feb 8

MergeQuant: Accurate 4-bit Static Quantization of Large Language Models by Channel-wise Calibration

Quantization has been widely used to compress and accelerate inference of large language models (LLMs). Existing methods focus on exploring the per-token dynamic calibration to ensure both inference acceleration and model accuracy under 4-bit quantization. However, in autoregressive generation inference of long sequences, the overhead of repeated dynamic quantization and dequantization steps becomes considerably expensive. In this work, we propose MergeQuant, an accurate and efficient per-channel static quantization framework. MergeQuant integrates the per-channel quantization steps with the corresponding scalings and linear mappings through a Quantization Step Migration (QSM) method, thereby eliminating the quantization overheads before and after matrix multiplication. Furthermore, in view of the significant differences between the different channel ranges, we propose dimensional reconstruction and adaptive clipping to address the non-uniformity of quantization scale factors and redistribute the channel variations to the subsequent modules to balance the parameter distribution under QSM. Within the static quantization setting of W4A4, MergeQuant reduces the accuracy gap on zero-shot tasks compared to FP16 baseline to 1.3 points on Llama-2-70B model. On Llama-2-7B model, MergeQuant achieves up to 1.77x speedup in decoding, and up to 2.06x speedup in end-to-end compared to FP16 baseline.

  • 9 authors
·
Mar 6, 2025

Amortized Opacity Marginalization Improves C/O Interval Calibration for Brown-Dwarf Retrievals

Molecular line lists disagree at a level that measurably shifts retrieved C/O, so retrievals conditioned on a single list omit a dominant systematic from their error bars. Classical marginalization re-runs a full retrieval under K opacity realizations per object. We move that cost into simulation: while generating the training set we randomize opacities (smooth multiplicative Fourier fields in logν plus a discrete line-list mixture, under a deliberately broad prior informed by measured inter-list differences), so a neural posterior estimator learns an already-marginalized posterior. Conceptually, this is the amortized analogue of repeating a conventional retrieval under many plausible opacity realizations and averaging the resulting posteriors. On perturbed held-out spectra (n=2048) a standard NPE covers nominal 90% C/O intervals 43.3% of the time against 82.4% for a compute-matched marginalized network; three-seed control ensembles reach 93.2% on clean data but 61.4% under perturbation, against 89.4% marginalized, isolating the deficit as opacity-induced (TARP joint expected-coverage deviation 0.005 against 0.035). An axis ablation traces the gain to the continuous field (45.4% for the discrete swaps alone, 79.3% for the field alone). Applying the 105 real bad-pixel masks with median filling then collapsed the ensemble's C/O coverage from 0.901 to 0.479; retraining on the same mask distribution and pooling three such seeds returns a nominal 0.905 C/O and 0.891 overall under the full deployment path, still in simulation (n=1024, same 105 masks), at 0.21 to 0.31 of the prior width. On 105 JWST/G395H spectral products of 13 late-T/Y dwarfs, single marginalized networks bracket the Hood et al. (2024) T8 benchmark C/O where the control excludes it, a consistency check rather than a validation, at 1.6-2.6x wider intervals.

  • 1 authors
·
Aug 31

When Implausible Tokens Get Reinforced: Tail-Aware Credit Calibration for LLM Reinforcement Learning

Reinforcement learning (RL) has achieved remarkable success in enhancing the reasoning capabilities of large language models (LLMs). However, widely used critic-free RL methods rely on uniform credit assignment, broadcasting the same advantage to all tokens regardless of their differences. We identify a critical failure mode of this design, which we refer to as Positive-Credit Contamination: low-probability tail tokens that are contextually erroneous receive identical positive credit to plausible ones within the same trajectory, resulting in the indiscriminate reinforcement of flawed reasoning behavior. To mitigate this issue, we propose Tail-Aware Credit calibratiOn (TACO), a method that calibrates uniform credit assignment to suppress undesirable positive updates. TACO first computes a tail-risk score that incorporates the local generation context to assess each token's risk of falling into the unreliable tail, distinguishing unexpected rarity from uncertainty-driven exploration. TACO then uses this score to tune positive credit for risky tokens without removing their gradients entirely, so that recurring useful rare patterns can accumulate reinforcement while incidental noise is progressively dampened. Experimental results across three LLMs and eight benchmarks show that TACO consistently outperforms GRPO-style baselines. Notably, TACO improves training stability, supporting sustained performance gains in long-horizon RL. The source code is available at: https://github.com/xiuyilou/TACO.

  • 7 authors
·
Jul 7

HEART: Exploiting Head Heterogeneity in Sparse Attention for Video Diffusion

Sparse attention accelerates video diffusion by allowing each attention head to focus on only a small subset of interactions. Existing methods already construct head-specific sparse patterns conditioned on the input. However, we find that these heads also differ in two less obvious but practically important ways. First, for some heads, sparse attention masks remain stable across many denoising steps, whereas others change rapidly. Second, heads differ substantially in their sensitivity to sparsification: applying the same threshold can induce markedly different errors in the final denoising velocity. Ignoring these differences leads to redundant mask prediction and suboptimal threshold calibration across heads under a global sparsity budget. We present HEART, short for Heterogeneity-Exploiting Adaptive Refresh and Thresholding, a training-free framework that exploits both forms of head heterogeneity. First, Temporal Mask Reuse (TMR) uses a lightweight per-head query-key drift signal to determine whether a cached sparse mask remains reliable across denoising steps, refreshing it only when the drift exceeds a prescribed threshold. Second, Error-guided Budgeted Calibration (EBC) evaluates candidate thresholds offline using a frequency-weighted denoising-velocity error, and assigns each head an appropriate threshold under a global sparsity budget. HEART requires no retraining, weight modification, or sparse-kernel changes, and can be integrated directly into existing sparse-attention pipelines. Across Wan2.1-1.3B, Wan2.1-14B, and HunyuanVideo-13B, HEART consistently pushes the quality--efficiency frontier of advanced sparse attention methods such as XAttention and SVG2 outward.

  • 6 authors
·
Aug 8

Measuring Calibration in Deep Learning

Overconfidence and underconfidence in machine learning classifiers is measured by calibration: the degree to which the probabilities predicted for each class match the accuracy of the classifier on that prediction. How one measures calibration remains a challenge: expected calibration error, the most popular metric, has numerous flaws which we outline, and there is no clear empirical understanding of how its choices affect conclusions in practice, and what recommendations there are to counteract its flaws. In this paper, we perform a comprehensive empirical study of choices in calibration measures including measuring all probabilities rather than just the maximum prediction, thresholding probability values, class conditionality, number of bins, bins that are adaptive to the datapoint density, and the norm used to compare accuracies to confidences. To analyze the sensitivity of calibration measures, we study the impact of optimizing directly for each variant with recalibration techniques. Across MNIST, Fashion MNIST, CIFAR-10/100, and ImageNet, we find that conclusions on the rank ordering of recalibration methods is drastically impacted by the choice of calibration measure. We find that conditioning on the class leads to more effective calibration evaluations, and that using the L2 norm rather than the L1 norm improves both optimization for calibration metrics and the rank correlation measuring metric consistency. Adaptive binning schemes lead to more stablity of metric rank ordering when the number of bins vary, and is also recommended. We open source a library for the use of our calibration measures.

  • 7 authors
·
Aug 6, 2020

Verified Uncertainty Calibration

Applications such as weather forecasting and personalized medicine demand models that output calibrated probability estimates---those representative of the true likelihood of a prediction. Most models are not calibrated out of the box but are recalibrated by post-processing model outputs. We find in this work that popular recalibration methods like Platt scaling and temperature scaling are (i) less calibrated than reported, and (ii) current techniques cannot estimate how miscalibrated they are. An alternative method, histogram binning, has measurable calibration error but is sample inefficient---it requires O(B/ε^2) samples, compared to O(1/ε^2) for scaling methods, where B is the number of distinct probabilities the model can output. To get the best of both worlds, we introduce the scaling-binning calibrator, which first fits a parametric function to reduce variance and then bins the function values to actually ensure calibration. This requires only O(1/ε^2 + B) samples. Next, we show that we can estimate a model's calibration error more accurately using an estimator from the meteorological community---or equivalently measure its calibration error with fewer samples (O(B) instead of O(B)). We validate our approach with multiclass calibration experiments on CIFAR-10 and ImageNet, where we obtain a 35% lower calibration error than histogram binning and, unlike scaling methods, guarantees on true calibration. In these experiments, we also estimate the calibration error and ECE more accurately than the commonly used plugin estimators. We implement all these methods in a Python library: https://pypi.org/project/uncertainty-calibration

  • 3 authors
·
Sep 23, 2019

A Benchmark Study on Calibration

Deep neural networks are increasingly utilized in various machine learning tasks. However, as these models grow in complexity, they often face calibration issues, despite enhanced prediction accuracy. Many studies have endeavored to improve calibration performance through the use of specific loss functions, data preprocessing and training frameworks. Yet, investigations into calibration properties have been somewhat overlooked. Our study leverages the Neural Architecture Search (NAS) search space, offering an exhaustive model architecture space for thorough calibration properties exploration. We specifically create a model calibration dataset. This dataset evaluates 90 bin-based and 12 additional calibration measurements across 117,702 unique neural networks within the widely employed NATS-Bench search space. Our analysis aims to answer several longstanding questions in the field, using our proposed dataset: (i) Can model calibration be generalized across different datasets? (ii) Can robustness be used as a calibration measurement? (iii) How reliable are calibration metrics? (iv) Does a post-hoc calibration method affect all models uniformly? (v) How does calibration interact with accuracy? (vi) What is the impact of bin size on calibration measurement? (vii) Which architectural designs are beneficial for calibration? Additionally, our study bridges an existing gap by exploring calibration within NAS. By providing this dataset, we enable further research into NAS calibration. As far as we are aware, our research represents the first large-scale investigation into calibration properties and the premier study of calibration issues within NAS. The project page can be found at https://www.taolinwei.com/calibration-study

  • 5 authors
·
Aug 22, 2023

Optimizing Calibration by Gaining Aware of Prediction Correctness

Model calibration aims to align confidence with prediction correctness. The Cross-Entropy (CE) loss is widely used for calibrator training, which enforces the model to increase confidence on the ground truth class. However, we find the CE loss has intrinsic limitations. For example, for a narrow misclassification, a calibrator trained by the CE loss often produces high confidence on the wrongly predicted class (e.g., a test sample is wrongly classified and its softmax score on the ground truth class is around 0.4), which is undesirable. In this paper, we propose a new post-hoc calibration objective derived from the aim of calibration. Intuitively, the proposed objective function asks that the calibrator decrease model confidence on wrongly predicted samples and increase confidence on correctly predicted samples. Because a sample itself has insufficient ability to indicate correctness, we use its transformed versions (e.g., rotated, greyscaled and color-jittered) during calibrator training. Trained on an in-distribution validation set and tested with isolated, individual test samples, our method achieves competitive calibration performance on both in-distribution and out-of-distribution test sets compared with the state of the art. Further, our analysis points out the difference between our method and commonly used objectives such as CE loss and mean square error loss, where the latters sometimes deviates from the calibration aim.

  • 5 authors
·
Apr 19, 2024

On the Limitations of Temperature Scaling for Distributions with Overlaps

Despite the impressive generalization capabilities of deep neural networks, they have been repeatedly shown to be overconfident when they are wrong. Fixing this issue is known as model calibration, and has consequently received much attention in the form of modified training schemes and post-training calibration procedures such as temperature scaling. While temperature scaling is frequently used because of its simplicity, it is often outperformed by modified training schemes. In this work, we identify a specific bottleneck for the performance of temperature scaling. We show that for empirical risk minimizers for a general set of distributions in which the supports of classes have overlaps, the performance of temperature scaling degrades with the amount of overlap between classes, and asymptotically becomes no better than random when there are a large number of classes. On the other hand, we prove that optimizing a modified form of the empirical risk induced by the Mixup data augmentation technique can in fact lead to reasonably good calibration performance, showing that training-time calibration may be necessary in some situations. We also verify that our theoretical results reflect practice by showing that Mixup significantly outperforms empirical risk minimization (with respect to multiple calibration metrics) on image classification benchmarks with class overlaps introduced in the form of label noise.

  • 2 authors
·
Jun 1, 2023

CalArena: A Large-Scale Post-Hoc Calibration Benchmark

Reliable probability estimates are critical in many machine learning applications, yet modern classifiers are often poorly calibrated. Post-hoc calibration provides a simple and widely used solution, but the large number of proposed methods, combined with small-scale and inconsistent evaluations, makes it difficult to determine which approaches are truly effective in practice. We introduce a large-scale, standardized benchmark for post-hoc calibration, covering nearly 2000 experiments across tabular and computer vision tasks, including binary, multiclass, and large-scale classification settings. Our benchmark aggregates predictions from a diverse set of classical models, modern deep learning architectures, and foundation models, and provides unified, reproducible implementations of dozens of calibration methods within a common evaluation framework. We argue that Post-Hoc Improvement (PHI) in proper scoring rules offers a principled alternative to traditional calibration error estimators for comparing post-hoc methods, capturing both calibration quality and potential degradation to the model's predictive performance. Using this framework, we conduct the most comprehensive empirical study of post-hoc calibration to date. Our results reveal consistent patterns across domains: smooth calibration functions outperform binning-based approaches, dedicated multiclass methods are essential in high-dimensional settings, and generic machine learning models are not competitive without calibration-specific design. To facilitate future research, we release all data, code, and evaluation tools, providing a plug-and-play benchmark for developing and comparing calibration methods.

  • 4 authors
·
May 27

h-calibration: Rethinking Classifier Recalibration with Probabilistic Error-Bounded Objective

Deep neural networks have demonstrated remarkable performance across numerous learning tasks but often suffer from miscalibration, resulting in unreliable probability outputs. This has inspired many recent works on mitigating miscalibration, particularly through post-hoc recalibration methods that aim to obtain calibrated probabilities without sacrificing the classification performance of pre-trained models. In this study, we summarize and categorize previous works into three general strategies: intuitively designed methods, binning-based methods, and methods based on formulations of ideal calibration. Through theoretical and practical analysis, we highlight ten common limitations in previous approaches. To address these limitations, we propose a probabilistic learning framework for calibration called h-calibration, which theoretically constructs an equivalent learning formulation for canonical calibration with boundedness. On this basis, we design a simple yet effective post-hoc calibration algorithm. Our method not only overcomes the ten identified limitations but also achieves markedly better performance than traditional methods, as validated by extensive experiments. We further analyze, both theoretically and experimentally, the relationship and advantages of our learning objective compared to traditional proper scoring rule. In summary, our probabilistic framework derives an approximately equivalent differentiable objective for learning error-bounded calibrated probabilities, elucidating the correspondence and convergence properties of computational statistics with respect to theoretical bounds in canonical calibration. The theoretical effectiveness is verified on standard post-hoc calibration benchmarks by achieving state-of-the-art performance. This research offers valuable reference for learning reliable likelihood in related fields.

  • 6 authors
·
Jun 22, 2025

Proximity-Informed Calibration for Deep Neural Networks

Confidence calibration is central to providing accurate and interpretable uncertainty estimates, especially under safety-critical scenarios. However, we find that existing calibration algorithms often overlook the issue of *proximity bias*, a phenomenon where models tend to be more overconfident in low proximity data (i.e., data lying in the sparse region of the data distribution) compared to high proximity samples, and thus suffer from inconsistent miscalibration across different proximity samples. We examine the problem over 504 pretrained ImageNet models and observe that: 1) Proximity bias exists across a wide variety of model architectures and sizes; 2) Transformer-based models are relatively more susceptible to proximity bias than CNN-based models; 3) Proximity bias persists even after performing popular calibration algorithms like temperature scaling; 4) Models tend to overfit more heavily on low proximity samples than on high proximity samples. Motivated by the empirical findings, we propose ProCal, a plug-and-play algorithm with a theoretical guarantee to adjust sample confidence based on proximity. To further quantify the effectiveness of calibration algorithms in mitigating proximity bias, we introduce proximity-informed expected calibration error (PIECE) with theoretical analysis. We show that ProCal is effective in addressing proximity bias and improving calibration on balanced, long-tail, and distribution-shift settings under four metrics over various model architectures. We believe our findings on proximity bias will guide the development of *fairer and better-calibrated* models, contributing to the broader pursuit of trustworthy AI. Our code is available at: https://github.com/MiaoXiong2320/ProximityBias-Calibration.

  • 7 authors
·
Jun 7, 2023

Calibration and Correctness of Language Models for Code

Machine learning models are widely used, but can also often be wrong. Users would benefit from a reliable indication of whether a given output from a given model should be trusted, so a rational decision can be made whether to use the output or not. For example, outputs can be associated with a confidence measure; if this confidence measure is strongly associated with likelihood of correctness, then the model is said to be well-calibrated. A well-calibrated confidence measure can serve as a basis for rational, graduated decision-making on how much review and care is needed when using generated code. Calibration has so far been studied in mostly non-generative (e.g. classification) settings, especially in software engineering. However, generated code can quite often be wrong: Given generated code, developers must decide whether to use directly, use after varying intensity of careful review, or discard model-generated code. Thus, calibration is vital in generative settings. We make several contributions. We develop a framework for evaluating the calibration of code-generating models. We consider several tasks, correctness criteria, datasets, and approaches, and find that, by and large, generative code models we test are not well-calibrated out of the box. We then show how calibration can be improved using standard methods, such as Platt scaling. Since Platt scaling relies on the prior availability of correctness data, we evaluate the applicability and generalizability of Platt scaling in software engineering, discuss settings where it has good potential for practical use, and settings where it does not. Our contributions will lead to better-calibrated decision-making in the current use of code generated by language models, and offers a framework for future research to further improve calibration methods for generative models in software engineering.

  • 9 authors
·
Feb 3, 2024

On Calibration of Object Detectors: Pitfalls, Evaluation and Baselines

Reliable usage of object detectors require them to be calibrated -- a crucial problem that requires careful attention. Recent approaches towards this involve (1) designing new loss functions to obtain calibrated detectors by training them from scratch, and (2) post-hoc Temperature Scaling (TS) that learns to scale the likelihood of a trained detector to output calibrated predictions. These approaches are then evaluated based on a combination of Detection Expected Calibration Error (D-ECE) and Average Precision. In this work, via extensive analysis and insights, we highlight that these recent evaluation frameworks, evaluation metrics, and the use of TS have notable drawbacks leading to incorrect conclusions. As a step towards fixing these issues, we propose a principled evaluation framework to jointly measure calibration and accuracy of object detectors. We also tailor efficient and easy-to-use post-hoc calibration approaches such as Platt Scaling and Isotonic Regression specifically for object detection task. Contrary to the common notion, our experiments show that once designed and evaluated properly, post-hoc calibrators, which are extremely cheap to build and use, are much more powerful and effective than the recent train-time calibration methods. To illustrate, D-DETR with our post-hoc Isotonic Regression calibrator outperforms the recent train-time state-of-the-art calibration method Cal-DETR by more than 7 D-ECE on the COCO dataset. Additionally, we propose improved versions of the recently proposed Localization-aware ECE and show the efficacy of our method on these metrics as well. Code is available at: https://github.com/fiveai/detection_calibration.

  • 4 authors
·
May 30, 2024

Do Large Language Models Know What They Don't Know? Kalshibench: A New Benchmark for Evaluating Epistemic Calibration via Prediction Markets

A well-calibrated model should express confidence that matches its actual accuracy -- when it claims 80\% confidence, it should be correct 80\% of the time. While large language models (LLMs) have achieved remarkable performance across diverse tasks, their epistemic calibration remains poorly understood. We introduce KalshiBench, a benchmark of 300 prediction market questions from Kalshi, a CFTC-regulated exchange, with verifiable real-world outcomes occurring after model training cutoffs. Unlike traditional benchmarks measuring accuracy on static knowledge, KalshiBench evaluates whether models can appropriately quantify uncertainty about genuinely unknown future events. We evaluate five frontier models -- Claude Opus 4.5, GPT-5.2, DeepSeek-V3.2, Qwen3-235B, and Kimi-K2 -- and find systematic overconfidence across all models. Even the best-calibrated model (Claude Opus 4.5, ECE=0.120) shows substantial calibration errors, while reasoning-enhanced models like GPT-5.2-XHigh exhibit worse calibration (ECE=0.395) despite comparable accuracy. Critically, only one model achieves a positive Brier Skill Score, indicating most models perform worse than simply predicting base rates. Our findings suggest that scaling and enhanced reasoning do not automatically confer calibration benefits, highlighting epistemic calibration as a distinct capability requiring targeted development.

  • 1 authors
·
Dec 17, 2025

Self-Calibration and Bilinear Inverse Problems via Linear Least Squares

Whenever we use devices to take measurements, calibration is indispensable. While the purpose of calibration is to reduce bias and uncertainty in the measurements, it can be quite difficult, expensive, and sometimes even impossible to implement. We study a challenging problem called self-calibration, i.e., the task of designing an algorithm for devices so that the algorithm is able to perform calibration automatically. More precisely, we consider the setup y = A(d) x + epsilon where only partial information about the sensing matrix A(d) is known and where A(d) linearly depends on d. The goal is to estimate the calibration parameter d (resolve the uncertainty in the sensing process) and the signal/object of interests x simultaneously. For three different models of practical relevance, we show how such a bilinear inverse problem, including blind deconvolution as an important example, can be solved via a simple linear least squares approach. As a consequence, the proposed algorithms are numerically extremely efficient, thus potentially allowing for real-time deployment. We also present a variation of the least squares approach, which leads to a~spectral method, where the solution to the bilinear inverse problem can be found by computing the singular vector associated with the smallest singular value of a certain matrix derived from the bilinear system. Explicit theoretical guarantees and stability theory are derived for both techniques; and the number of sampling complexity is nearly optimal (up to a poly-log factor). Applications in imaging sciences and signal processing are discussed and numerical simulations are presented to demonstrate the effectiveness and efficiency of our approach.

  • 2 authors
·
Nov 13, 2016

Rethinking Post-Hoc Calibration in Semantic Segmentation

Reliable confidence estimates are essential in semantic segmentation, especially in safety-critical settings where overconfident errors can mislead downstream decisions. Yet modern segmentation models often remain miscalibrated. Post-hoc calibration offers a practical way to correct confidence estimates without retraining the segmentation model, but its use in dense prediction raises structural issues that are often overlooked. We study two such issues. First, adding a constant to all logits leaves the softmax probabilities unchanged, but several standard calibrators can still depend on this arbitrary offset. As a result, two logit representations encoding the same predictive distribution may yield different calibrated probabilities. We define translation-invariant (TI) calibrators as those whose outputs are unchanged under such shifts, characterize which common calibrators satisfy this property, and construct TI counterparts of shift-sensitive calibrators to isolate the effect of removing representation dependence. Second, post-hoc calibration is typically fitted by minimizing a likelihood-based objective, whereas segmentation models are trained with task-specific metrics such as Dice. This mismatch can cause calibration to alter class orderings and degrade the deployed segmentation map. We study decision-preserving calibration under argmax- and order-preservation constraints. Since enforcing these constraints collapses affine softmax calibrators to temperature scaling, we introduce class-conditional affine calibrators that can be made argmax- or order-preserving while retaining greater expressivity, allowing us to quantify the calibration-segmentation trade-off induced by decision preservation. Across natural-image and medical segmentation benchmarks, and under corruption-based covariate shift, matched comparisons show that TI variants generally improve calibration metrics, while decision-preserving variants prevent segmentation degradation and retain strong calibration performance. These results provide practical design principles for well-defined post-hoc calibration pipelines in semantic segmentation.

MIC-DKFZ MIC at DKFZ
·
Jul 1

Let Confidence Change, Not the Prediction: Prediction-Preserving Repair for Post-hoc Calibration

Post-hoc calibration corrects reported confidence, yet a multiclass calibrator can also change the associated top-1 prediction. Accuracy captures only the net effect of these changes on correctness, not how often predictions change; the Top-1 Prediction Change Rate (TPCR) instead measures this frequency. We propose Calibrator-Output Repair for Top-1 Decision Preservation (CORD), the first post-fit adapter to impose exact prediction preservation by repairing the full calibrated probability vector. From the original and calibrated outputs alone, CORD determines the mass assigned to the original top-1. The calibrated conditional distribution allocates the remaining mass over the other classes, yielding a repaired vector whose own argmax recovers the original prediction. On the calibration split, CORD coordinates the repaired masses to retain the calibrated outputs' mean mass on original predictions whenever attainable. The adapter alters neither the fitted calibrator nor its direct output, fits no additional supervised map, and requires no user- or validation-tuned hyperparameter. Across CIFAR-10/100 and ImageNet-1K, CORD attains zero TPCR by construction and lowers mean ECE, NLL, and Brier relative to the corresponding direct outputs in every dataset; paired gains persist under distribution shift and across calibration-set sizes. CORD thus removes the preservation constraint from calibrator fitting and assigns exact recovery of the original decision to subsequent output repair. Our code is available at https://github.com/labhai/CORD.

  • 3 authors
·
Sep 1 2

On Task Performance and Model Calibration with Supervised and Self-Ensembled In-Context Learning

Following the standard supervised fine-tuning (SFT) paradigm, in-context learning (ICL) has become an efficient approach propelled by the recent advancements in large language models (LLMs), yielding promising performance across various tasks in few-shot data setups. However, both paradigms are prone to suffer from the critical problem of overconfidence (i.e., miscalibration), especially in such limited data setups. In this work, we deliver an in-depth analysis of the behavior across different choices of learning methods from the perspective of both performance and calibration, as well as their interplay. Through extensive controlled experiments, we find that simultaneous gains for both task performance and calibration are difficult to achieve, and the problem of miscalibration exists across all learning methods in low-resource scenarios. To address this challenging trade-off between performance and calibration, we then investigate the potential of self-ensembling techniques applied at different modeling stages (e.g., variations of in-context examples or variations in prompts or different ensembling strategies). We justify the feasibility of self-ensembling on SFT in addition to ICL, to make the predictions more calibrated and have comparable or even better performance. Our work sheds light on which learning paradigm to choose and how to enhance both task performance and calibration of LLMs.

  • 5 authors
·
Dec 21, 2023

What are the Desired Characteristics of Calibration Sets? Identifying Correlates on Long Form Scientific Summarization

Summarization models often generate text that is poorly calibrated to quality metrics because they are trained to maximize the likelihood of a single reference (MLE). To address this, recent work has added a calibration step, which exposes a model to its own ranked outputs to improve relevance or, in a separate line of work, contrasts positive and negative sets to improve faithfulness. While effective, much of this work has focused on how to generate and optimize these sets. Less is known about why one setup is more effective than another. In this work, we uncover the underlying characteristics of effective sets. For each training instance, we form a large, diverse pool of candidates and systematically vary the subsets used for calibration fine-tuning. Each selection strategy targets distinct aspects of the sets, such as lexical diversity or the size of the gap between positive and negatives. On three diverse scientific long-form summarization datasets (spanning biomedical, clinical, and chemical domains), we find, among others, that faithfulness calibration is optimal when the negative sets are extractive and more likely to be generated, whereas for relevance calibration, the metric margin between candidates should be maximized and surprise--the disagreement between model and metric defined candidate rankings--minimized. Code to create, select, and optimize calibration sets is available at https://github.com/griff4692/calibrating-summaries

  • 10 authors
·
May 12, 2023 1

Beyond Probability Partitions: Calibrating Neural Networks with Semantic Aware Grouping

Research has shown that deep networks tend to be overly optimistic about their predictions, leading to an underestimation of prediction errors. Due to the limited nature of data, existing studies have proposed various methods based on model prediction probabilities to bin the data and evaluate calibration error. We propose a more generalized definition of calibration error called Partitioned Calibration Error (PCE), revealing that the key difference among these calibration error metrics lies in how the data space is partitioned. We put forth an intuitive proposition that an accurate model should be calibrated across any partition, suggesting that the input space partitioning can extend beyond just the partitioning of prediction probabilities, and include partitions directly related to the input. Through semantic-related partitioning functions, we demonstrate that the relationship between model accuracy and calibration lies in the granularity of the partitioning function. This highlights the importance of partitioning criteria for training a calibrated and accurate model. To validate the aforementioned analysis, we propose a method that involves jointly learning a semantic aware grouping function based on deep model features and logits to partition the data space into subsets. Subsequently, a separate calibration function is learned for each subset. Experimental results demonstrate that our approach achieves significant performance improvements across multiple datasets and network architectures, thus highlighting the importance of the partitioning function for calibration.

  • 3 authors
·
Jun 8, 2023

Taming Overconfidence in LLMs: Reward Calibration in RLHF

Language model calibration refers to the alignment between the confidence of the model and the actual performance of its responses. While previous studies point out the overconfidence phenomenon in Large Language Models (LLMs) and show that LLMs trained with Reinforcement Learning from Human Feedback (RLHF) are overconfident with a more sharpened output probability, in this study, we reveal that RLHF tends to lead models to express verbalized overconfidence in their own responses. We investigate the underlying cause of this overconfidence and demonstrate that reward models used for Proximal Policy Optimization (PPO) exhibit inherent biases towards high-confidence scores regardless of the actual quality of responses. Building upon this insight, we propose two PPO variants: PPO-M: PPO with Calibrated Reward Modeling and PPO-C: PPO with Calibrated Reward Calculation. PPO-M integrates explicit confidence scores in reward model training, which calibrates reward models to better capture the alignment between response quality and verbalized confidence. PPO-C adjusts the reward score during PPO based on the difference between the current reward and the moving average of past rewards. Both PPO-M and PPO-C can be seamlessly integrated into the current PPO pipeline and do not require additional golden labels. We evaluate our methods on both Llama3-8B and Mistral-7B across six diverse datasets including multiple-choice and open-ended generation. Experiment results demonstrate that both of our methods can reduce calibration error and maintain performance comparable to standard PPO. We further show that they do not compromise model capabilities in open-ended conversation settings.

  • 4 authors
·
Oct 13, 2024 2

Language Models Agree With Each Other, Not With Readers

Claims that language models homogenise are usually measured against human judgements collected for the study, which makes the human side an artifact of the design: a crowdworker given the model's instruction is running the model's prompt. We measure convergence against a human reference nobody built for the purpose -- 2,523 reader mark sets across 120 web documents, produced by people highlighting for their own reasons on a platform where the overlay of others' marks is off by default. Agreement is the overlap between two size-matched sentence sets minus the overlap expected when each is resampled within its own depth-and-length bands. The null's calibration is demonstrated, not asserted: every pair involving a random baseline lands within 0.006 of zero. On the median document each party names 14 sentences of 70; two readers share 4.1 and two models 8.7. Across 18 model arms spanning 11 vendors, 3 countries and both weight regimes, the median of 153 model pairs is +0.093 against a human yardstick of +0.040, and 99 sit entirely above the human interval. Two frontier models from rival labs reach +0.203, twice what GPT-4o agrees with itself on a second call. The effect is not determinism, prompt wording, procedure, vendor or routing, and it is graded: the smallest models agree at the human level. No model agrees with readers detectably more than a reader does, and at equal depth and length no surface feature separates their choices. The multiples are procedure-dependent and the ordering is not: models are cut to their sharpest set while a reader's is a random draw from what they marked, and blunting the models alike halves the gap without closing it. Tested out of sample on four models released after this analysis, against predictions fixed beforehand, none clears the human interval. A population simulated from several models is not several populations.

  • 2 authors
·
Jul 30

Thinking with Nothinking Calibration: A New In-Context Learning Paradigm in Reasoning Large Language Models

Reasoning large language models (RLLMs) have recently demonstrated remarkable capabilities through structured and multi-step reasoning. While prior research has primarily focused on improving their training and inference strategies, their potential for in-context learning (ICL) remains largely underexplored. To fill this gap, we propose Thinking with Nothinking Calibration (JointThinking), a new ICL paradigm that leverages the structured difference between two reasoning modes, i.e., Thinking and Nothinking, to improve reasoning accuracy. Specifically, our method prompts the model to generate two answers in parallel: one in Thinking mode and the other in Nothinking mode. A second round of Thinking is triggered only when the two initial responses are inconsistent, using a single prompt that incorporates the original question and both candidate answers. Since such disagreement occurs infrequently (e.g., only 6\% in GSM8K), our method performs just one round of reasoning in most cases, resulting in minimal latency overhead. Extensive experiments across multiple reasoning benchmarks demonstrate that JointThinking significantly outperforms few-shot chain-of-thought (CoT) and majority voting with improved answer robustness. Moreover, It achieves comparable in-distribution performance to training-based SOTA method, while substantially outperforming on out-of-distribution tasks. We further conduct a systematic analysis of the calibration mechanism, showing that leveraging different reasoning modes consistently lowers the error rate and highlights the value of structural thinking diversity. Additionally, we observe that the performance gap between actual and ideal reasoning narrows as model size increases in the second round of thinking, indicating the strong scalability of our approach. Finally, we discuss current limitations and outline promising directions for future ICL research in RLLMs.

  • 5 authors
·
Aug 5, 2025

PD-Quant: Post-Training Quantization based on Prediction Difference Metric

Post-training quantization (PTQ) is a neural network compression technique that converts a full-precision model into a quantized model using lower-precision data types. Although it can help reduce the size and computational cost of deep neural networks, it can also introduce quantization noise and reduce prediction accuracy, especially in extremely low-bit settings. How to determine the appropriate quantization parameters (e.g., scaling factors and rounding of weights) is the main problem facing now. Existing methods attempt to determine these parameters by minimize the distance between features before and after quantization, but such an approach only considers local information and may not result in the most optimal quantization parameters. We analyze this issue and ropose PD-Quant, a method that addresses this limitation by considering global information. It determines the quantization parameters by using the information of differences between network prediction before and after quantization. In addition, PD-Quant can alleviate the overfitting problem in PTQ caused by the small number of calibration sets by adjusting the distribution of activations. Experiments show that PD-Quant leads to better quantization parameters and improves the prediction accuracy of quantized models, especially in low-bit settings. For example, PD-Quant pushes the accuracy of ResNet-18 up to 53.14% and RegNetX-600MF up to 40.67% in weight 2-bit activation 2-bit. The code is released at https://github.com/hustvl/PD-Quant.

  • 6 authors
·
Dec 14, 2022

Evaluating Large-Vocabulary Object Detectors: The Devil is in the Details

By design, average precision (AP) for object detection aims to treat all classes independently: AP is computed independently per category and averaged. On one hand, this is desirable as it treats all classes equally. On the other hand, it ignores cross-category confidence calibration, a key property in real-world use cases. Unfortunately, under important conditions (i.e., large vocabulary, high instance counts) the default implementation of AP is neither category independent, nor does it directly reward properly calibrated detectors. In fact, we show that on LVIS the default implementation produces a gameable metric, where a simple, un-intuitive re-ranking policy can improve AP by a large margin. To address these limitations, we introduce two complementary metrics. First, we present a simple fix to the default AP implementation, ensuring that it is independent across categories as originally intended. We benchmark recent LVIS detection advances and find that many reported gains do not translate to improvements under our new evaluation, suggesting recent improvements may arise from difficult to interpret changes to cross-category rankings. Given the importance of reliably benchmarking cross-category rankings, we consider a pooled version of AP (AP-Pool) that rewards properly calibrated detectors by directly comparing cross-category rankings. Finally, we revisit classical approaches for calibration and find that explicitly calibrating detectors improves state-of-the-art on AP-Pool by 1.7 points

  • 5 authors
·
Feb 1, 2021

CaliBench: Are the Stochastic Dynamics of Video World Models Physically Calibrated?

Video world models approximate the stochastic distribution of physical outcomes through generative sampling, but existing benchmarks score individual generations or compare distributions coarsely over a whole dataset, leaving the fine-grained aleatoric uncertainty of specific phenomena untested. We introduce CaliBench, which scores outcomes in a physically interpretable discrete space - a bin index, a die face, a suit, a colour - rather than a learned feature space such as in FID, so the distance from a known reference distribution is measured directly. We curate outcome spaces whose reference is known in closed form (binomial Galton boards, Bernoulli forks, uniform dice/cards/lottery, a skewed European-roulette colour), enabling an exact calibration test. We decompose performance into two orthogonal axes that a single accuracy metric conflates: scorability, the fraction of generations yielding a scoreable outcome, and calibration, the total variation distance from the reference on that sample. A chi-squared test assesses significance; as calibration is its null hypothesis it can evidence only miscalibration, and at N=32 per cell detects only large deviations. We apply it to nine scenes and six image-to-video models (WAN-2.7, SeeDance-2.0, HappyHorse-1.0, Veo 3.1, Runway Gen-4.5, Cosmos3-Super), 32 generations each. Models consistently concentrate probability mass on a few outcomes rather than reproducing the reference. Most scene-model combinations are significantly miscalibrated, in the extreme collapsing to one outcome, as Veo 3.1 does on dice. On roulette, generations often leave the ball ambiguously placed, giving several models low scorability. Performance varies by scene: no model dominates all nine. We release the protocol and a metric (mean normalised total variation, mnTV) for comparing new models against our results.

  • 6 authors
·
Aug 16

What Single-Prompt Accuracy Misses: A Multi-Variant Reliability Audit of Language Models

Single-prompt accuracy is the dominant way to benchmark language models, but it can miss reliability failures that matter. We evaluate a 15-model open-weight corpus, with the main reliability analyses focused on 10 instruct models across five classification and reasoning benchmarks under five prompt variants each, measuring accuracy, token-probability calibration, verbal-confidence calibration, verbal parse rate, and prompt-perturbation spread for every (model x dataset x variant) cell. We find three broad results. First, evaluation design can materially change the conclusion. Switching Expected Calibration Error (ECE) token from a raw to a label-set-normalised definition changes per-cell calibration by a mean absolute 0.149. More strikingly, pairing a chain-of-thought prompt with a first-character evaluator on ARC-Challenge reduces apparent accuracy by 72-88% across all five primary models; two independent repair procedures recover 93.8% and 102.7% of the lost performance, indicating an evaluator-side rather than model-side failure. Second, confidence signals are fragile. On MMLU-Pro, every primary model verbally reports confidence substantially above both its accuracy and its token-probability confidence on the same rows, and verbal parse rate can collapse for a single model on a single prompt variant. Third, prompt robustness does not track parameter count reliably. Across 10 instruct models, the correlation between model size and prompt-perturbation spread ranges from -0.244 to 0.474 across benchmarks. Taken together, these results show that reliability conclusions for small language models depend not only on the model being evaluated, but also on the evaluation pipeline used to measure it. We argue that calibration definitions, evaluator logic, verbal parseability, and prompt robustness should be reported explicitly when making reliability claims.

  • 2 authors
·
May 2

QUIJOTE scientific results -- IV. A northern sky survey in intensity and polarization at 10-20GHz with the Multi-Frequency Instrument

We present QUIJOTE intensity and polarization maps in four frequency bands centred around 11, 13, 17 and 19GHz, and covering approximately 29000 deg^2, including most of the Northern sky region. These maps result from 9000 h of observations taken between May 2013 and June 2018 with the first QUIJOTE instrument (MFI), and have angular resolutions of around 1^circ, and sensitivities in polarization within the range 35-40 μK per 1-degree beam, being a factor sim 2-4 worse in intensity. We discuss the data processing pipeline employed, and the basic characteristics of the maps in terms of real space statistics and angular power spectra. A number of validation tests have been applied to characterise the accuracy of the calibration and the residual level of systematic effects, finding a conservative overall calibration uncertainty of 5%. We also discuss flux densities for four bright celestial sources (Tau A, Cas A, Cyg A and 3C274) which are often used as calibrators at microwave frequencies. The polarization signal in our maps is dominated by synchrotron emission. The distribution of spectral index values between the 11GHz and WMAP 23GHz map peaks at β=-3.09 with a standard deviation of 0.14. The measured BB/EE ratio at scales of ell=80 is 0.26pm 0.07 for a Galactic cut |b|>10^circ. We find a positive TE correlation for 11GHz at large angular scales (ell lesssim 50), while the EB and TB signals are consistent with zero in the multipole range 30 lesssim ell lesssim 150. The maps discussed in this paper are publicly available.

  • 38 authors
·
Jan 11, 2023

Colorimetric skin tone scale for improved accuracy and reduced perceptual bias of human skin tone annotations

Human image datasets used to develop and evaluate technology should represent the diversity of human phenotypes, including skin tone. Datasets that include skin tone information frequently rely on manual skin tone ratings based on the Fitzpatrick Skin Type (FST) or the Monk Skin Tone (MST) scales in lieu of the actual measured skin tone of the image dataset subjects. However, perceived skin tone is subject to known biases and skin tone appearance in digital images can vary substantially depending on the capture camera and environment, confounding manual ratings. Surprisingly, the relationship between skin-tone ratings and measured skin tone has not been explored. To close this research gap, we measured the relationship between skin tone ratings from existing scales (FST, MST) and skin tone values measured by a calibrated colorimeter. We also propose and assess a novel Colorimetric Skin Tone (CST) scale developed based on prior colorimetric measurements. Using experiments requiring humans to rate their own skin tone and the skin tone of subjects in images, we show that the new CST scale is more sensitive, consistent, and colorimetrically accurate. While skin tone ratings appeared to correct for some color variation across images, they introduced biases related to race and other factors. These biases must be considered before using manual skin-tone ratings in technology evaluations or for engineering decisions.

  • 7 authors
·
Oct 27, 2024

RankMixup: Ranking-Based Mixup Training for Network Calibration

Network calibration aims to accurately estimate the level of confidences, which is particularly important for employing deep neural networks in real-world systems. Recent approaches leverage mixup to calibrate the network's predictions during training. However, they do not consider the problem that mixtures of labels in mixup may not accurately represent the actual distribution of augmented samples. In this paper, we present RankMixup, a novel mixup-based framework alleviating the problem of the mixture of labels for network calibration. To this end, we propose to use an ordinal ranking relationship between raw and mixup-augmented samples as an alternative supervisory signal to the label mixtures for network calibration. We hypothesize that the network should estimate a higher level of confidence for the raw samples than the augmented ones (Fig.1). To implement this idea, we introduce a mixup-based ranking loss (MRL) that encourages lower confidences for augmented samples compared to raw ones, maintaining the ranking relationship. We also propose to leverage the ranking relationship among multiple mixup-augmented samples to further improve the calibration capability. Augmented samples with larger mixing coefficients are expected to have higher confidences and vice versa (Fig.1). That is, the order of confidences should be aligned with that of mixing coefficients. To this end, we introduce a novel loss, M-NDCG, in order to reduce the number of misaligned pairs of the coefficients and confidences. Extensive experimental results on standard benchmarks for network calibration demonstrate the effectiveness of RankMixup.

  • 4 authors
·
Aug 23, 2023

Retrieval-Corrected Conformal Prediction for Time Series

Conformal prediction (CP) provides distribution-free prediction intervals for fixed forecasters, but its standard calibration procedure is often inefficient for time series data, where forecast errors are temporally dependent and change across time and operating conditions. Recent time series CP methods improve local calibration using recent, weighted, or localized residuals. Yet local calibration can remain indirect, since broad residual weighting or additional adaptation procedures may dilute the evidence most relevant to the current prediction. This motivates a simple retrieval and correction strategy that selects similar past residuals as local evidence and then corrects the coverage error left by retrieval. In this paper, we propose Retrieval--Corrected Conformal Prediction (RCCP), a retrieval-augmented calibration method for time series prediction intervals. RCCP builds an asymmetric interval from retrieved one-sided residuals and calibrates its normalized retrieval error with a scalar conformal correction. Thus, retrieval provides local residual evidence, while conformal correction determines the final scale needed for coverage. We provide a coverage-gap bound based on the stability of the normalized retrieval error distribution. Across standard benchmarks and backbone forecasters, RCCP attains the target coverage in every setting and achieves the lowest Winkler scores, with fewer severe misses. RCCP also achieves low calibration and inference overhead, showing that retrieval-corrected calibration is an effective and scalable approach to uncertainty quantification in time series forecasting. Code is available at https://github.com/jinsaaang/rccp.

  • 4 authors
·
Aug 10

Planck 2018 results. III. High Frequency Instrument data processing and frequency maps

This paper presents the High Frequency Instrument (HFI) data processing procedures for the Planck 2018 release. Major improvements in mapmaking have been achieved since the previous 2015 release. They enabled the first significant measurement of the reionization optical depth parameter using HFI data. This paper presents an extensive analysis of systematic effects, including the use of simulations to facilitate their removal and characterize the residuals. The polarized data, which presented a number of known problems in the 2015 Planck release, are very significantly improved. Calibration, based on the CMB dipole, is now extremely accurate and in the frequency range 100 to 353 GHz reduces intensity-to-polarization leakage caused by calibration mismatch. The Solar dipole direction has been determined in the three lowest HFI frequency channels to within one arc minute, and its amplitude has an absolute uncertainty smaller than 0.35μK, an accuracy of order 10^{-4}. This is a major legacy from the HFI for future CMB experiments. The removal of bandpass leakage has been improved by extracting the bandpass-mismatch coefficients for each detector as part of the mapmaking process; these values in turn improve the intensity maps. This is a major change in the philosophy of "frequency maps", which are now computed from single detector data, all adjusted to the same average bandpass response for the main foregrounds. Simulations reproduce very well the relative gain calibration of detectors, as well as drifts within a frequency induced by the residuals of the main systematic effect. Using these simulations, we measure and correct the small frequency calibration bias induced by this systematic effect at the 10^{-4} level. There is no detectable sign of a residual calibration bias between the first and second acoustic peaks in the CMB channels, at the 10^{-3} level.

  • 155 authors
·
Jul 16, 2018

Self-Anchoring Calibration Drift in Large Language Models: How Multi-Turn Conversations Reshape Model Confidence

We introduce Self-Anchoring Calibration Drift (SACD), a hypothesized tendency for large language models (LLMs) to show systematic changes in expressed confidence when building iteratively on their own prior outputs across multi-turn conversations. We report an empirical study comparing three frontier models -- Claude Sonnet 4.6, Gemini 3.1 Pro, and GPT-5.2 -- across 150 questions spanning factual, technical, and open-ended domains, using three conditions: single-turn baseline (A), multi-turn self-anchoring (B), and independent repetition control (C). Results reveal a complex, model-heterogeneous pattern that partially diverges from pre-registered hypotheses. Claude Sonnet 4.6 exhibited significant decreasing confidence under self-anchoring (mean CDS = -0.032, t(14) = -2.43, p = .029, d = -0.627), while also showing significant calibration error drift (F(4,56) = 22.77, p < .001, eta^2 = .791). GPT-5.2 showed the opposite pattern in open-ended domains (mean CDS = +0.026) with significant ECE escalation by Turn 5. Gemini 3.1 Pro showed no significant CDS (t(14) = 0.38, p = .710), but its Condition C data reveals a striking ECE pattern: without self-anchoring, Gemini's calibration error drops from .327 to near zero across repetitions, whereas self-anchoring holds ECE flat at approximately .333 -- indicating that SACD can manifest as suppression of natural calibration improvement rather than ac

  • 1 authors
·
Feb 28

Improving Metacognition and Uncertainty Communication in Language Models

Large language models (LLMs) are increasingly used in decision-making contexts, but when they present answers without signaling low confidence, users may unknowingly act on erroneous outputs. Prior work shows that LLMs maintain internal uncertainty signals, yet their expressed confidence is often miscalibrated and poorly discriminates between correct and incorrect answers. We investigate whether supervised fine-tuning can improve models' ability to communicate uncertainty and whether such improvements generalize across tasks and domains. We fine-tune LLMs on datasets spanning general knowledge, mathematics, and open-ended trivia, and evaluate two metacognitive tasks: (1) single-question confidence estimation, where the model assigns a numeric certainty to its answer, and (2) pairwise confidence comparison, where the model selects which of two answers it is more likely to answer correctly. We assess generalization to unseen domains, including medical and legal reasoning. Results show that fine-tuning improves calibration (alignment between stated confidence and accuracy) and discrimination (higher confidence for correct vs. incorrect responses) within and across domains. However, gains are task-specific: training on single-question calibration does not transfer to pairwise comparison, and vice versa. Multitask fine-tuning yields broader gains, lowering calibration error and strengthening discrimination in out-of-domain evaluations. This suggests that uncertainty communication in LLMs is trainable but requires multitask training to generalize effectively.

  • 3 authors
·
Sep 30, 2025

Is C4 Dataset Optimal for Pruning? An Investigation of Calibration Data for LLM Pruning

Network pruning has emerged as a potential solution to make LLMs cheaper to deploy. However, existing LLM pruning approaches universally rely on the C4 dataset as the calibration data for calculating pruning scores, leaving its optimality unexplored. In this study, we evaluate the choice of calibration data on LLM pruning, across a wide range of datasets that are most commonly used in LLM training and evaluation, including four pertaining datasets as well as three categories of downstream tasks encompassing nine datasets. Each downstream dataset is prompted with In-Context Learning (ICL) and Chain-of-Thought (CoT), respectively. Besides the already intriguing observation that the choice of calibration data significantly impacts the performance of pruned LLMs, our results also uncover several subtle and often unexpected findings, summarized as follows: (1) C4 is not the optimal choice for LLM pruning, even among commonly used pre-training datasets; (2) arithmetic datasets, when used as calibration data, performs on par or even better than pre-training datasets; (3) pruning with downstream datasets does not necessarily help the corresponding downstream task, compared to pre-training data; (4) ICL is widely beneficial to all data categories, whereas CoT is only useful on certain tasks. Our findings shed light on the importance of carefully selecting calibration data for LLM pruning and pave the way for more efficient deployment of these powerful models in real-world applications. We release our code at: https://github.com/abx393/llm-pruning-calibration-data.

  • 8 authors
·
Oct 8, 2024

Deep Learning for Camera Calibration and Beyond: A Survey

Camera calibration involves estimating camera parameters to infer geometric features from captured sequences, which is crucial for computer vision and robotics. However, conventional calibration is laborious and requires dedicated collection. Recent efforts show that learning-based solutions have the potential to be used in place of the repeatability works of manual calibrations. Among these solutions, various learning strategies, networks, geometric priors, and datasets have been investigated. In this paper, we provide a comprehensive survey of learning-based camera calibration techniques, by analyzing their strengths and limitations. Our main calibration categories include the standard pinhole camera model, distortion camera model, cross-view model, and cross-sensor model, following the research trend and extended applications. As there is no unified benchmark in this community, we collect a holistic calibration dataset that can serve as a public platform to evaluate the generalization of existing methods. It comprises both synthetic and real-world data, with images and videos captured by different cameras in diverse scenes. Toward the end of this paper, we discuss the challenges and provide further research directions. To our knowledge, this is the first survey for the learning-based camera calibration (spanned 10 years). The summarized methods, datasets, and benchmarks are available and will be regularly updated at https://github.com/KangLiao929/Awesome-Deep-Camera-Calibration.

  • 8 authors
·
Mar 19, 2023

Calibrating Beyond English: Language Diversity for Better Quantized Multilingual LLM

Quantization is an effective technique for reducing the storage footprint and computational costs of Large Language Models (LLMs), but it often results in performance degradation. Existing post-training quantization methods typically use small, English-only calibration sets; however, their impact on multilingual models remains underexplored. We systematically evaluate eight calibration settings (five single-language and three multilingual mixes) on two quantizers (GPTQ, AWQ) on data from 10 languages. Our findings reveal a consistent trend: non-English and multilingual calibration sets significantly improve perplexity compared to English-only baselines. Specifically, we observe notable average perplexity gains across both quantizers on Llama3.1 8B and Qwen2.5 7B, with multilingual mixes achieving the largest overall reductions of up to 3.52 points in perplexity. Furthermore, our analysis indicates that tailoring calibration sets to the evaluation language yields the largest improvements for individual languages, underscoring the importance of linguistic alignment. We also identify specific failure cases where certain language-quantizer combinations degrade performance, which we trace to differences in activation range distributions across languages. These results highlight that static one-size-fits-all calibration is suboptimal and that tailoring calibration data, both in language and diversity, plays a crucial role in robustly quantizing multilingual LLMs.

  • 3 authors
·
Jan 25

Prior Availability in Industrial Visual Sim-to-Real: A Review of CAD-Guided and CAD-Unavailable Regimes

Industrial visual sim-to-real is often described as transferring from synthetic images to real images, but industrial deployment usually involves a broader mismatch between available evidence and required decisions. A system may be built from CAD renderings, simulated RGB-D observations, normal reference images, synthetic defects, pretrained feature spaces, or language prompts, yet deployed under different sensors, lighting, materials, fixtures, calibration, production variation, and rare defect modes. This review reframes industrial visual sim-to-real as a domain-gap problem organized by prior availability. We distinguish CAD-available settings, where explicit object geometry can support rendering, calibration, pose estimation, segmentation, and test-time geometric verification; CAD-unavailable settings, where geometry is replaced by normal-reference appearance, feature distributions, teacher-student residuals, synthetic anomaly assumptions, foundation features, or vision-language priors; and boundary-prior settings, where approximate models, templates, reference views, or semantic correspondences preserve only part of the CAD role. This framing connects CAD-based detection and 6D pose-estimation literature with industrial anomaly and surface-inspection literature that is usually reviewed separately. To make the taxonomy concrete, we use empirical anchors on T-LESS/BOP, MVTec AD, and VisA. The anchors show that CAD render count alone does not close transfer; source-distribution design, detector capacity, and small real calibration can matter more. They also show that CAD at test time creates a distinct verification channel through mask, pose, and depth consistency, whereas CAD-unavailable inspection relies on calibrated normality and feature deviation. The review therefore argues against a single cross-task leaderboard and instead asks what prior grounds the deployment decision.

  • 2 authors
·
May 27 1

Online Reasoning Calibration: Test-Time Training Enables Generalizable Conformal LLM Reasoning

While test-time scaling has enabled large language models to solve highly difficult tasks, state-of-the-art results come at exorbitant compute costs. These inefficiencies can be attributed to the miscalibration of post-trained language models, and the lack of calibration in popular sampling techniques. Here, we present Online Reasoning Calibration (ORCA), a framework for calibrating the sampling process that draws upon conformal prediction and test-time training. Specifically, we introduce a meta-learning procedure that updates the calibration module for each input. This allows us to provide valid confidence estimates under distributional shift, e.g. in thought patterns that occur across different stages of reasoning, or in prompt distributions between model development and deployment. ORCA not only provides theoretical guarantees on conformal risks, but also empirically shows higher efficiency and generalization across different reasoning tasks. At risk level δ=0.1, ORCA improves Qwen2.5-32B efficiency on in-distribution tasks with savings up to 47.5% with supervised labels and 40.7% with self-consistency labels. Under zero-shot out-of-domain settings, it improves MATH-500 savings from 24.8% of the static calibration baseline to 67.0% while maintaining a low empirical error rate, and the same trend holds across model families and downstream benchmarks. Our code is publicly available at https://github.com/wzekai99/ORCA.

  • 9 authors
·
Mar 31

Same Model, Different Harness: Different Coding-Agent Results

A coding agent combines a model with a harness, which decides what the model sees, which tools it can use, and how the work continues. We ask whether changing the harness changes the result when the model and task stay fixed. We compare two configurations of the same harness on three coding benchmarks. The control supplies the full conversation in time order, while the treatment keeps the same record but mechanically shortens older tool results as the context fills and responds to repeated or stalled work. Under tight context, the treatment raises mean per-task fail-to-pass fraction (F2PF) in all three pressure comparisons and increases complete solutions on SWE-bench Verified and SWE-bench Pro. The tight-window Verified comparison uses 169 tasks, a 20,480-token window, and a fixed 480-second attempt endpoint; on this cohort, treatment raises mean per-task F2PF from 28 percent to 49 percent and complete solutions from 43 to 72. Without model-specific retuning, the same frozen treatment also raises both endpoints on the same cohort for three additional models with different designs. In the wide-window Qwen3.6 comparisons, observed arm outcomes are close on Verified and Pro, while FeatureBench retains a higher mean per-task F2PF under treatment. On the wide-window Verified cohort, treatment also serves fewer prompt tokens per turn. Because changing the harness changed what unchanged model weights could accomplish, coding-agent evaluations should treat the model and harness together as the tested solver.

  • 1 authors
·
Aug 25

When Noisy Labels Meet Long Tail Dilemmas: A Representation Calibration Method

Real-world large-scale datasets are both noisily labeled and class-imbalanced. The issues seriously hurt the generalization of trained models. It is hence significant to address the simultaneous incorrect labeling and class-imbalance, i.e., the problem of learning with noisy labels on long-tailed data. Previous works develop several methods for the problem. However, they always rely on strong assumptions that are invalid or hard to be checked in practice. In this paper, to handle the problem and address the limitations of prior works, we propose a representation calibration method RCAL. Specifically, RCAL works with the representations extracted by unsupervised contrastive learning. We assume that without incorrect labeling and class imbalance, the representations of instances in each class conform to a multivariate Gaussian distribution, which is much milder and easier to be checked. Based on the assumption, we recover underlying representation distributions from polluted ones resulting from mislabeled and class-imbalanced data. Additional data points are then sampled from the recovered distributions to help generalization. Moreover, during classifier training, representation learning takes advantage of representation robustness brought by contrastive learning, which further improves the classifier performance. We derive theoretical results to discuss the effectiveness of our representation calibration. Experiments on multiple benchmarks justify our claims and confirm the superiority of the proposed method.

  • 5 authors
·
Nov 20, 2022

Through the Haze: a Non-Convex Approach to Blind Gain Calibration for Linear Random Sensing Models

Computational sensing strategies often suffer from calibration errors in the physical implementation of their ideal sensing models. Such uncertainties are typically addressed by using multiple, accurately chosen training signals to recover the missing information on the sensing model, an approach that can be resource-consuming and cumbersome. Conversely, blind calibration does not employ any training signal, but corresponds to a bilinear inverse problem whose algorithmic solution is an open issue. We here address blind calibration as a non-convex problem for linear random sensing models, in which we aim to recover an unknown signal from its projections on sub-Gaussian random vectors, each subject to an unknown positive multiplicative factor (or gain). To solve this optimisation problem we resort to projected gradient descent starting from a suitable, carefully chosen initialisation point. An analysis of this algorithm allows us to show that it converges to the exact solution provided a sample complexity requirement is met, i.e., relating convergence to the amount of information collected during the sensing process. Interestingly, we show that this requirement grows linearly (up to log factors) in the number of unknowns of the problem. This sample complexity is found both in absence of prior information, as well as when subspace priors are available for both the signal and gains, allowing a further reduction of the number of observations required for our recovery guarantees to hold. Moreover, in the presence of noise we show how our descent algorithm yields a solution whose accuracy degrades gracefully with the amount of noise affecting the measurements. Finally, we present some numerical experiments in an imaging context, where our algorithm allows for a simple solution to blind calibration of the gains in a sensor array.

  • 2 authors
·
Oct 27, 2016

The Confidence Dichotomy: Analyzing and Mitigating Miscalibration in Tool-Use Agents

Autonomous agents based on large language models (LLMs) are rapidly evolving to handle multi-turn tasks, but ensuring their trustworthiness remains a critical challenge. A fundamental pillar of this trustworthiness is calibration, which refers to an agent's ability to express confidence that reliably reflects its actual performance. While calibration is well-established for static models, its dynamics in tool-integrated agentic workflows remain underexplored. In this work, we systematically investigate verbalized calibration in tool-use agents, revealing a fundamental confidence dichotomy driven by tool type. Specifically, our pilot study identifies that evidence tools (e.g., web search) systematically induce severe overconfidence due to inherent noise in retrieved information, while verification tools (e.g., code interpreters) can ground reasoning through deterministic feedback and mitigate miscalibration. To robustly improve calibration across tool types, we propose a reinforcement learning (RL) fine-tuning framework that jointly optimizes task accuracy and calibration, supported by a holistic benchmark of reward designs. We demonstrate that our trained agents not only achieve superior calibration but also exhibit robust generalization from local training environments to noisy web settings and to distinct domains such as mathematical reasoning. Our results highlight the necessity of domain-specific calibration strategies for tool-use agents. More broadly, this work establishes a foundation for building self-aware agents that can reliably communicate uncertainty in high-stakes, real-world deployments.

  • 6 authors
·
Jan 12 2

Improving Post Training Neural Quantization: Layer-wise Calibration and Integer Programming

Lately, post-training quantization methods have gained considerable attention, as they are simple to use, and require only a small unlabeled calibration set. This small dataset cannot be used to fine-tune the model without significant over-fitting. Instead, these methods only use the calibration set to set the activations' dynamic ranges. However, such methods always resulted in significant accuracy degradation, when used below 8-bits (except on small datasets). Here we aim to break the 8-bit barrier. To this end, we minimize the quantization errors of each layer separately by optimizing its parameters over the calibration set. We empirically demonstrate that this approach is: (1) much less susceptible to over-fitting than the standard fine-tuning approaches, and can be used even on a very small calibration set; and (2) more powerful than previous methods, which only set the activations' dynamic ranges. Furthermore, we demonstrate how to optimally allocate the bit-widths for each layer, while constraining accuracy degradation or model compression by proposing a novel integer programming formulation. Finally, we suggest model global statistics tuning, to correct biases introduced during quantization. Together, these methods yield state-of-the-art results for both vision and text models. For instance, on ResNet50, we obtain less than 1\% accuracy degradation --- with 4-bit weights and activations in all layers, but the smallest two. We open-sourced our code.

  • 5 authors
·
Jun 14, 2020

WARP: Wasserstein-Aligned RAG for Population Opinions

RAG systems are increasingly used to summarize what large collections of documents say. A user asks "What do people think about X?" and receives an answer that reads as consensus. But standard top-k retrieval ranks documents by query similarity, not by how faithfully they represent the population, so minority views quietly disappear. Existing fixes fall short. Diversity re-rankers like MMR and DPP spread retrieved documents apart, but with no target distribution to aim for. Calibration methods based on KL or JS divergence do target one, yet treat opinion bins as unordered: confusing strong positive with strong negative costs no more than an adjacent-bin miss. We introduce WARP, a family of post-retrieval algorithms that calibrate retrieved evidence to the population's opinion distribution. WARP first recovers underrepresented opinions that cosine ranking may bury, then uses Wasserstein-1 distance to select documents whose sentiment-intensity distribution matches the population target, capturing the ordinal structure ignored by KL and JS divergence. We develop three variants for dense, sparse, and variable candidate pools, trading off calibration quality and speed. Across three review domains spanning 35K documents, 156 queries, and 26 entities, WARP's domain-matched variants reduce distributional error by at least 43% with sub-second latency. These gains carry through to generation: a five-judge LLM panel prefers WARP-generated answers in 86% of decided comparisons at k <= 5.

  • 4 authors
·
Aug 23

gPhoton: The GALEX Photon Data Archive

gPhoton is a new database product and software package that enables analysis of GALEX ultraviolet data at the photon level. The project's stand-alone, pure-Python calibration pipeline reproduces the functionality of the original mission pipeline to reduce raw spacecraft data to lists of time-tagged, sky-projected photons, which are then hosted in a publicly available database by the Mikulski Archive at Space Telescope (MAST). This database contains approximately 130 terabytes of data describing approximately 1.1 trillion sky-projected events with a timestamp resolution of five milliseconds. A handful of Python and command line modules serve as a front-end to interact with the database and to generate calibrated light curves and images from the photon-level data at user-defined temporal and spatial scales. The gPhoton software and source code are in active development and publicly available under a permissive license. We describe the motivation, design, and implementation of the calibration pipeline, database, and tools, with emphasis on divergence from prior work, as well as challenges created by the large data volume. We summarize the astrometric and photometric performance of gPhoton relative to the original mission pipeline. For a brief example of short time domain science capabilities enabled by gPhoton, we show new flares from the known M dwarf flare star CR Draconis. The gPhoton software has permanent object identifiers with the ASCL (ascl:1603.004) and DOI (doi:10.17909/T9CC7G). This paper describes the software as of version v1.27.2.

  • 9 authors
·
Sep 28, 2016

Jev thinks "I don't know'', but doesn't say it: Introducing Sys1Cal-v1 Dataset for Probability Calibration

The appearance of Jev marked the era of System One Models, foundation models that return structured decisions with probability distributions rather than text. Aside from low cost and great speed, Jev's central promise is that these probabilities are calibrated: such claim is not backed by any public test and available external benchmarks evaluate confidence calibration, not whether every returned option probability has the right numerical meaning. To tackle this issue, we introduce Sys1Cal-v1, a dataset of True/False questions about a proposition A for which the exact probability P(A) is known by construction. Each item is queried through the three Jev primitives - Noul, Choice and Score - and evaluated by total variation distance from the ground-truth distribution, which can be used to estimate a soft accuracy of System One Models. We showcase the utility of Sys1Cal-v1 as a benchmark dataset by evaluating Jev and SemIf, an open-source Choice-style baseline. In this work, however, we focus even more deeply on Jev, by studying the calibration of its Score and Choice answers. In particular, we discover a peculiar behaviour that can be explained by assuming that Jev suppresses a third truth value, going beyond True and False. In other words, in Choice answers, P(A) and P(neg A) are presented as if P(A)+P(neg A)=1, while a term P(U)neq0 is missing in the sum. Recovering P(U) leads to an improvement of median soft accuracy in Choice answers from 0.771 to 0.978, suggesting that, even in binary decisions, Jev wants to answer with a third option:``I don't know''.

  • 1 authors
·
Sep 27 1

QuantSightBench: Evaluating LLM Quantitative Forecasting with Prediction Intervals

Forecasting has become a natural benchmark for reasoning under uncertainty. Yet existing evaluations of large language models remain limited to judgmental tasks in simple formats, such as binary or multiple-choice questions. In practice, however, forecasting spans a far broader scope. Across domains such as economics, public health, and social demographics, decisions hinge on numerical estimates over continuous quantities, a capability that current benchmarks do not capture. Evaluating such estimates requires a format that makes uncertainty explicit and testable. We propose prediction intervals as a natural and rigorous interface for this purpose. They demand scale awareness, internal consistency across confidence levels, and calibration over a continuum of outcomes, making them a more suitable evaluation format than point estimates for numerical forecasting. To assess this capability, we introduce a new benchmark QuantSightBench, and evaluate frontier models under multiple settings, assessing both empirical coverage and interval sharpness. Our results show that none of the 11 evaluated frontier and open-weight models achieves the 90\% coverage target, with the top performers Gemini 3.1 Pro (79.1\%), Grok 4 (76.4\%), and GPT-5.4 (75.3\%) all falling at least 10 percentage points short. Calibration degrades sharply at extreme magnitudes, revealing systematic overconfidence across all evaluated models.

  • 2 authors
·
Apr 16

The Gini-Bayes Connection: The CAP Slope as Bayes' Theorem, with Applications to Weight of Evidence, Somers' D, and Calibration

The probabilistic reading of the cumulative accuracy profile (CAP) has a long industry lineage. Falkenstein, Boral and Carty (2000) state, in discrete form, that the default rate at a score percentile equals the portfolio average rate times the local slope of the power curve; van der Burgt (2008, 2019) formalizes this as the continuous identity p(Dmid x) = p_D, dy/dx and imports the continuous form as a working fact; Tasche (2009) analyzes the resulting calibration method; Voloshyn and Voloshyn (2023) substitute Bayes' theorem, f(xmid D)=p(Dmid x) f(x)/p_D, into the area integral and write the Gini as a functional of the calibration curve. The slope itself is already in the lineage (van der Burgt's dy/dx is the ratio of the two cumulative differentials), but it enters as a cited working fact, never as Bayes' theorem. We make that identification explicit and draw out its consequences. First, the CAP slope is Bayes' theorem in cumulative coordinates: the standardized PD it recovers is the posterior probability rescaled by the prior. The weight of the paper then falls on two results this reading unlocks. The odds form places the weight of evidence (the log of the likelihood ratio, i.e. the Bayes factor) and the information value inside one geometry (the weight of evidence at a point is the log of the ratio of the "bad" and "good" CAP slopes). The accuracy ratio, Somers' D_{xy}, and the Gini (2A-1)/(1-p_D) are revealed as one number computed three ways. Run in comparison mode (realized outcomes against model claims), the same identity recovers the reliability diagram in cumulative coordinates, with the sign of the gap between the empirical and model-implied Gini coefficients as a calibration diagnostic. A worked five-band example carries every identity in discrete form, and a kernel-density example extends them to the continuous case.

  • 1 authors
·
Jun 15