new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 13

A Clinical-grade Universal Foundation Model for Intraoperative Pathology

Intraoperative pathology is pivotal to precision surgery, yet its clinical impact is constrained by diagnostic complexity and the limited availability of high-quality frozen-section data. While computational pathology has made significant strides, the lack of large-scale, prospective validation has impeded its routine adoption in surgical workflows. Here, we introduce CRISP, a clinical-grade foundation model developed on over 100,000 frozen sections from eight medical centers, specifically designed to provide Clinical-grade Robust Intraoperative Support for Pathology (CRISP). CRISP was comprehensively evaluated on more than 15,000 intraoperative slides across nearly 100 retrospective diagnostic tasks, including benign-malignant discrimination, key intraoperative decision-making, and pan-cancer detection, etc. The model demonstrated robust generalization across diverse institutions, tumor types, and anatomical sites-including previously unseen sites and rare cancers. In a prospective cohort of over 2,000 patients, CRISP sustained high diagnostic accuracy under real-world conditions, directly informing surgical decisions in 92.6% of cases. Human-AI collaboration further reduced diagnostic workload by 35%, avoided 105 ancillary tests and enhanced detection of micrometastases with 87.5% accuracy. Together, these findings position CRISP as a clinical-grade paradigm for AI-driven intraoperative pathology, bridging computational advances with surgical precision and accelerating the translation of artificial intelligence into routine clinical practice.

  • 23 authors
·
Oct 11, 2025

KD-OCT: Efficient Knowledge Distillation for Clinical-Grade Retinal OCT Classification

Age-related macular degeneration (AMD) and choroidal neovascularization (CNV)-related conditions are leading causes of vision loss worldwide, with optical coherence tomography (OCT) serving as a cornerstone for early detection and management. However, deploying state-of-the-art deep learning models like ConvNeXtV2-Large in clinical settings is hindered by their computational demands. Therefore, it is desirable to develop efficient models that maintain high diagnostic performance while enabling real-time deployment. In this study, a novel knowledge distillation framework, termed KD-OCT, is proposed to compress a high-performance ConvNeXtV2-Large teacher model, enhanced with advanced augmentations, stochastic weight averaging, and focal loss, into a lightweight EfficientNet-B2 student for classifying normal, drusen, and CNV cases. KD-OCT employs real-time distillation with a combined loss balancing soft teacher knowledge transfer and hard ground-truth supervision. The effectiveness of the proposed method is evaluated on the Noor Eye Hospital (NEH) dataset using patient-level cross-validation. Experimental results demonstrate that KD-OCT outperforms comparable multi-scale or feature-fusion OCT classifiers in efficiency- accuracy balance, achieving near-teacher performance with substantial reductions in model size and inference time. Despite the compression, the student model exceeds most existing frameworks, facilitating edge deployment for AMD screening. Code is available at https://github.com/erfan-nourbakhsh/KD- OCT.

  • 3 authors
·
Dec 9, 2025 2

PathOrchestra: A Comprehensive Foundation Model for Computational Pathology with Over 100 Diverse Clinical-Grade Tasks

The complexity and variability inherent in high-resolution pathological images present significant challenges in computational pathology. While pathology foundation models leveraging AI have catalyzed transformative advancements, their development demands large-scale datasets, considerable storage capacity, and substantial computational resources. Furthermore, ensuring their clinical applicability and generalizability requires rigorous validation across a broad spectrum of clinical tasks. Here, we present PathOrchestra, a versatile pathology foundation model trained via self-supervised learning on a dataset comprising 300K pathological slides from 20 tissue and organ types across multiple centers. The model was rigorously evaluated on 112 clinical tasks using a combination of 61 private and 51 public datasets. These tasks encompass digital slide preprocessing, pan-cancer classification, lesion identification, multi-cancer subtype classification, biomarker assessment, gene expression prediction, and the generation of structured reports. PathOrchestra demonstrated exceptional performance across 27,755 WSIs and 9,415,729 ROIs, achieving over 0.950 accuracy in 47 tasks, including pan-cancer classification across various organs, lymphoma subtype diagnosis, and bladder cancer screening. Notably, it is the first model to generate structured reports for high-incidence colorectal cancer and diagnostically complex lymphoma-areas that are infrequently addressed by foundational models but hold immense clinical potential. Overall, PathOrchestra exemplifies the feasibility and efficacy of a large-scale, self-supervised pathology foundation model, validated across a broad range of clinical-grade tasks. Its high accuracy and reduced reliance on extensive data annotation underline its potential for clinical integration, offering a pathway toward more efficient and high-quality medical services.

  • 27 authors
·
Mar 31, 2025

Computer Vision for Clinical Gait Analysis: A Gait Abnormality Video Dataset

Clinical gait analysis (CGA) using computer vision is an emerging field in artificial intelligence that faces barriers of accessible, real-world data, and clear task objectives. This paper lays the foundation for current developments in CGA as well as vision-based methods and datasets suitable for gait analysis. We introduce The Gait Abnormality in Video Dataset (GAVD) in response to our review of over 150 current gait-related computer vision datasets, which highlighted the need for a large and accessible gait dataset clinically annotated for CGA. GAVD stands out as the largest video gait dataset, comprising 1874 sequences of normal, abnormal and pathological gaits. Additionally, GAVD includes clinically annotated RGB data sourced from publicly available content on online platforms. It also encompasses over 400 subjects who have undergone clinical grade visual screening to represent a diverse range of abnormal gait patterns, captured in various settings, including hospital clinics and urban uncontrolled outdoor environments. We demonstrate the validity of the dataset and utility of action recognition models for CGA using pretrained models Temporal Segment Networks(TSN) and SlowFast network to achieve video abnormality detection of 94% and 92% respectively when tested on GAVD dataset. A GitHub repository https://github.com/Rahmyyy/GAVD consisting of convenient URL links, and clinically relevant annotation for CGA is provided for over 450 online videos, featuring diverse subjects performing a range of normal, pathological, and abnormal gait patterns.

  • 4 authors
·
Jul 4, 2024

PRISM2: Unlocking Multi-Modal General Pathology AI with Clinical Dialogue

Recent rapid progress in the field of computational pathology has been enabled by foundation models. These models are beginning to move beyond encoding image patches towards whole-slide understanding but their clinical utility remains limited. In this work, we present PRISM2, a multimodal slide-level foundation model trained on data from 700,000 diagnostic specimen-report pairs, the largest vision (2.3 million whole slide images) and language (14M question-answer pairs) histopathology dataset to date. By learning through clinical-dialogue supervision, PRISM2 aligns histomorphologic features with the language of diagnostic reasoning, producing slide-level representations that support both direct diagnostic question-answering and transferable embeddings for downstream tasks. Without additional training, PRISM2 matches or exceeds the cancer-detection performance of clinical-grade products. This is observed without loss of generality on other tasks, where PRISM2 achieves top performance. Finally, using survival prediction as the example, we show that task-specific finetuning with a large dataset can outperform task-specific models, further improving performance. These results demonstrate how language-supervised pretraining provides a scalable, clinically grounded signal for learning generalizable pathology representations, bridging human diagnostic reasoning and foundation-model performance.

  • 19 authors
·
Oct 30, 2025

TLNM: Externally Validated Tooth Detection, Numbering and Segmentation from Smartphone Photographs Using Mask R-CNN

Oral health issues affect billions globally, but the cost and limited access to professional dental care hinder preventive oral healthcare. Research relies on clinical-grade radiographs or intraoral camera images, unavailable for public self-screening. This study introduces a tooth localisation and numbering model for smartphone photographs. We developed a customised Mask Region-based Convolutional Neural Network (Mask R-CNN) pipeline trained on 1,272 annotated smartphone images. To address variability in patient-generated health data, the pipeline incorporates two domain-informed mechanisms: a masked gray-world white-balancing algorithm to mitigate artificial colour casts and an anatomically constrained detection layer to enforce structural validity and suppress false positives. Evaluation comprised four stages: internal held-out testing, independent external testing, a descriptive ablation study, and fold-based training stability analysis using the same internal test set. On the internal test set, the model achieved an instance-mask AP@50 of 0.818, class-aware PQ of 0.780, and operational F1 of 0.884. Training stability showed limited between-model variation: across ten runs, instance-mask AP@50 had a standard deviation of 0.009. On the external dataset, the model achieved an instance-mask AP@50 of 0.901, class-aware PQ of 0.832, and operational F1 of 0.928 despite differences in population, sensors, and acquisition protocols. The inference pipeline is available as an open-source, containerised API. These results demonstrate that consumer-grade smartphone imagery can support automated tooth-level anatomical mapping, offering a scalable, potentially low-cost foundation for remote screening and tele-dentistry in resource-constrained environments.

  • 5 authors
·
Aug 5

OpenBrain: An Auditable Generated-Label Release for Whole-Brain MRI Parcellation

Automatic tools can now generate whole-brain MRI parcellations at cohort scale, but generated-label releases often provide little evidence about which cases are reliable enough to reuse. We introduce OpenBrain, a confidence-aware release of 35,838 provenance-verified OpenNeuro T1w cases from 607 source datasets. OpenBrain is organized as an auditable case-record release rather than a directory of standalone segmentation files: each record links a primary parcellation, two committee parcellations, source/license provenance, raw QC-7 measurements, percentile risks, a combined risk score R, and a confidence tier. QC-7 is a reference-free reliability panel over label geometry, image-label consistency, and committee disagreement, so users can filter, weight, audit, or re-threshold generated labels without rerunning inference. We evaluate this released evidence under a frozen protocol. Across external cohorts, lower QC-7 risk corresponds to higher generated-label quality; in fixed-budget training, lower-risk selections improve paired macro Dice over random selection by +3.2 to +3.7 percentage points. OpenBrain also exposes raw axes, committee outputs, provenance, and datasheet documentation, so confidence claims remain inspectable after download. It does not turn generated labels into manual annotations or clinical-grade segmentations. Its contribution is a large open generated-parcellation substrate, a reusable case-level risk-evidence layer, and an external validation protocol for release-time QC. Dataset: https://huggingface.co/datasets/lanqz7766/OpenBrain. Code: https://github.com/lanqz7766/openbrain.

  • 8 authors
·
Nov 2

PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection

In clinical practice, electrocardiography (ECG) remains the gold standard for cardiac monitoring, providing crucial insights for diagnosing a wide range of cardiovascular diseases (CVDs). However, its reliance on specialized equipment and trained personnel limits feasibility for continuous routine monitoring. Photoplethysmography (PPG) offers accessible, continuous monitoring but lacks definitive electrophysiological information, preventing conclusive diagnosis. Generative models present a promising approach to translate PPG into clinically valuable ECG signals, yet current methods face substantial challenges, including the misalignment of physiological semantics in generative models and the complexity of modeling in high-dimensional signals. To this end, we propose PPGFlowECG, a two-stage framework that aligns PPG and ECG in a shared latent space via the CardioAlign Encoder and employs latent rectified flow to generate ECGs with high fidelity and interpretability. To the best of our knowledge, this is the first study to experiment on MCMED, a newly released clinical-grade dataset comprising over 10 million paired PPG-ECG samples from more than 118,000 emergency department visits with expert-labeled cardiovascular disease annotations. Results demonstrate the effectiveness of our method for PPG-to-ECG translation and cardiovascular disease detection. Moreover, cardiologist-led evaluations confirm that the synthesized ECGs achieve high fidelity and improve diagnostic reliability, underscoring our method's potential for real-world cardiovascular screening.

  • 9 authors
·
Sep 24, 2025

Advancing Tabular Stroke Modelling Through a Novel Hybrid Architecture and Feature-Selection Synergy

Brain stroke remains one of the principal causes of death and disability worldwide, yet most tabular-data prediction models still hover below the 95% accuracy threshold, limiting real-world utility. Addressing this gap, the present work develops and validates a completely data-driven and interpretable machine-learning framework designed to predict strokes using ten routinely gathered demographic, lifestyle, and clinical variables sourced from a public cohort of 4,981 records. We employ a detailed exploratory data analysis (EDA) to understand the dataset's structure and distribution, followed by rigorous data preprocessing, including handling missing values, outlier removal, and class imbalance correction using Synthetic Minority Over-sampling Technique (SMOTE). To streamline feature selection, point-biserial correlation and random-forest Gini importance were utilized, and ten varied algorithms-encompassing tree ensembles, boosting, kernel methods, and a multilayer neural network-were optimized using stratified five-fold cross-validation. Their predictions based on probabilities helped us build the proposed model, which included Random Forest, XGBoost, LightGBM, and a support-vector classifier, with logistic regression acting as a meta-learner. The proposed model achieved an accuracy rate of 97.2% and an F1-score of 97.15%, indicating a significant enhancement compared to the leading individual model, LightGBM, which had an accuracy of 91.4%. Our study's findings indicate that rigorous preprocessing, coupled with a diverse hybrid model, can convert low-cost tabular data into a nearly clinical-grade stroke-risk assessment tool.

  • 3 authors
·
May 18, 2025

The strength of clinical evidence is recoverable from language model representations but not from their stated grades

Large language models (LLMs) increasingly summarize clinical evidence, where a claim's weight depends on how strongly it is supported. Yet these models convey confidence poorly, and properties they never state, such as truth, are often readable from their activations. Whether a clinical model registers evidence strength, distinct from truth, and states it when asked is untested, and any such signal could be lexical. We compiled 45,134 clinical claims from six public sources, harmonized 20,611 into a four-level evidence grade under three independent frameworks, and tested 22 local, open-weight LLMs from several developers (0.6-70 billion parameters; general, medical, and reasoning), with lexical, truth, and cross-framework controls. A linear estimator recovered the grade in every model (median AUROC 71.8), yet decodability did not rise with scale and was weakest in reasoning models. The grade the models stated fell to chance, 25-27 percentage points below the estimator. The recoverable signal was largely lexical and did not transfer across topics or frameworks, yet it was distinct from factual truth and still flagged weakly supported claims (AUROC 69.2). Clinical LLMs thus carry an ordered evidence-strength signal they do not express, so their stated grades fail to convey a claim's support even when it is recoverable from their representations and text.

  • 1 authors
·
Jun 26

Expert Evaluation of Clinical AI Tools on Real Point-of-Care Clinical Queries

Physicians now pose millions of clinical questions to AI tools each week, yet these tools are evaluated largely on hypothetical or exam-style questions, not those actually asked in practice. We report a blinded evaluation built on 620 Real-world Point-Of-Care Queries (Real-POCQi) submitted to the OpenEvidence (OE) platform by physicians spanning 30 specialties, as well as 187 questions from HealthBench. 149 practicing physicians across 36 states made head-to-head comparisons between answers from three frontier general-purpose models (Claude Opus 4.8, Gemini 3.1 Pro, and GPT-5.5) and a specialized clinical tool (OE), with graders matched to each question's specialty. When comparing answers along five dimensions relevant to clinical decision support -- accuracy, clinical utility, source quality, verifiability, & completeness -- physicians scored the specialized tool highest on all axes; in the primary analysis on Real-POCQi, win differences (margins between win and loss rates) ranged from 25 to 39 percentage points (p<0.001). Results remained consistent in sensitivity analyses stratifying by citation display, answer length, OE-user status, and Real-POCQi versus HealthBench. In parallel, LLM judges were found to systematically differ from expert judges, though both generally agreed on the best model. These findings underscore two conclusions: (i) AI tool evaluations should reflect real-world query distributions and use expert judges that mirror the specialization defining modern medicine and (ii) the consistent advantage of the specialized tool over general-purpose models does not necessarily mean that the latter cannot serve similar purposes, but that targeted engineering and customization can yield meaningful gains in performance for its users. We release Real-POCQi as a public benchmark, as well as the prespecified statistical analysis for reproducing results of this study.

  • 8 authors
·
Jun 26

Can "AI" Be a Doctor? A Study of Empathy, Readability, and Alignment in Clinical LLMs

Large Language Models (LLMs) are increasingly deployed in healthcare, yet their communicative alignment with clinical standards remains insufficiently quantified. We conduct a multidimensional evaluation of general-purpose and domain-specialized LLMs across structured medical explanations and real-world physician-patient interactions, analyzing semantic fidelity, readability, and affective resonance. Baseline models amplify affective polarity relative to physicians (Very Negative: 43.14-45.10% vs. 37.25%) and, in larger architectures such as GPT-5 and Claude, produce substantially higher linguistic complexity (FKGL up to 16.91-17.60 vs. 11.47-12.50 in physician-authored responses). Empathy-oriented prompting reduces extreme negativity and lowers grade-level complexity (up to -6.87 FKGL points for GPT-5) but does not significantly increase semantic fidelity. Collaborative rewriting yields the strongest overall alignment. Rephrase configurations achieve the highest semantic similarity to physician answers (up to mean = 0.93) while consistently improving readability and reducing affective extremity. Dual stakeholder evaluation shows that no model surpasses physicians on epistemic criteria, whereas patients consistently prefer rewritten variants for clarity and emotional tone. These findings suggest that LLMs function most effectively as collaborative communication enhancers rather than replacements for clinical expertise.

  • 7 authors
·
Apr 21

CLR-voyance: Reinforcing Open-Ended Reasoning for Inpatient Clinical Decision Support with Outcome-Aware Rubrics

Inpatient clinical reasoning is a sequential decision under partial observability: the clinician sees the admission so far and must choose the next action whose downstream consequences are not yet visible. Existing clinical-LLM evaluations and RL rewards signals collapse this into closed-form retrieval, clinical journey leakage, or unanchored LLM-as-judge scoring. We introduce CLR-voyance, a framework that reformulates inpatient reasoning as a Partially Observable Markov Decision Process (POMDP) and supervises it with rewards that are simultaneously outcome-grounded and clinician-validated. We instantiate the formulation as CLR-POMDP, which partitions successful patient journeys into a policy-visible past and an oracle-only future. Using the past information, an oracle LLM generates a case-specific query-answer pair, and the first adaptive rubric for clinical reasoning which is verifiable in the future of the patient journey. These rubrics are used for both post-training and evaluation of models for inpatient clinical reasoning. We post-train Qwen3-8B and MedGemma-4B with GRPO followed by model merging, yielding state-of-the-art inpatient clinical reasoning while retaining generalist capabilities. CLR-voyance-8B achieves 84.91% on CLR-POMDP, ahead of frontier medical reasoning models like GPT-5 (77.83%) and MedGemma-27B (66.66%) and has comparable or better performance on existing medical benchmarks. To ensure a clinically meaningful setting, we conduct a large-scale clinician alignment study, where physicians curate per-case rubrics, grade candidate responses, and provide blinded pairwise preferences of model reasoning. This study provides insights on clinical LLM-as-a-judge and clinical preference-model selection, which can inform the community at large. CLR-voyance has been deployed for 6+ months at a partner public hospital, drafting thousands of reasoning-heavy inpatient notes.

  • 8 authors
·
May 9

LLM Judges Verify Presence, Not Absence: Omission Blindness in AI Clinical Notes and What Recovers It

Ambient AI scribes draft clinical notes, and published audits find their dominant error is omission: information the encounter established that the note fails to record. The standard check is an LLM judge: a second model reads the note against the transcript and flags problems. We ask whether judges detect omissions. Public corpora cannot supply the answer key: their clinician reference notes and transcripts are materially discrepant. Our benchmark has 500 single-error note pairs from audited fact sheets, 298 with a named fact certainly absent and 202 added-or-altered controls. Across eight judge designs, paired discrimination (the flawed note below its clean twin, 0.5 a coin flip) reads 0.79-0.94 on added or altered content and 0.50-0.63 on omissions. On single notes, no design flags omissions reliably more often than perfect notes. Wording changes, voting and GEPA prompt optimisation move the operating point without creating usable detection. Restructuring the task recovers it: list the facts the transcript establishes, then check the note for each. Two methods reach it independently and trade off: a per-fact pipeline, and a GEPA-evolved prompt doing the same in one call. The pipeline's flags name the missing fact and its severity at 2.7% false alarms. The single call detects more (36.9% against 24.6%, p=0.002) at 6.2% false alarms and a tenth of the cost per note. A physician author validated 70 items and, where the two routes disagree, sided with the pipeline on 10 of 10 (p=0.002). A second clinician, not an author, graded the severity rubric blind and agrees to within a grade. On real vendor notes from a companion census no benchmark threshold transfers, but the re-calibrated single call detects more than the best of the eight at half its false-alarm rate. Omissions whose fact is restated elsewhere defeat both routes. We release the benchmark, prompts and judgements.

  • 4 authors
·
Aug 30

Symphony for Speech-to-Text: Supporting Real-Time Medical Voice Interfaces

After decades of use in dictation and, more recently, ambient documentation, speech is emerging as a primary modality for interacting with technology and AI in healthcare. Yet medical speech recognition remains difficult: systems must capture specialized terminology, resolve contextual ambiguity, and render measurements, abbreviations, and clinical shorthand precisely. Existing solutions are typically optimized either for general-purpose transcription or narrow dictation workflows, limiting their reliability in safety-critical settings and their usefulness for broader clinical workflows. We introduce Symphony for Speech-to-Text, a medical-grade speech recognition system for real-time streaming and batch file-based clinical use. Symphony decomposes the transcription process into specialized components for recognition, formatting, and contextual correction to optimize medical term recall while producing clinically structured text in real time and adapting across use cases. Evaluations on public benchmark and medical speech datasets show that Symphony substantially outperforms state-of-the-art systems in clinical settings while matching or exceeding them in general-domain settings, suggesting robust generalization rather than overfitting. We release a clinical benchmark dataset to support reliable validation and further progress in medical speech recognition. Symphony is available through a production-grade API for live dictation, conversational transcription, and batch audio file processing.

  • 9 authors
·
May 20

SimSUM: Simulated Benchmark with Structured and Unstructured Medical Records

Clinical information extraction, which involves structuring clinical concepts from unstructured medical text, remains a challenging problem that could benefit from the inclusion of tabular background information available in electronic health records. Existing open-source datasets lack explicit links between structured features and clinical concepts in the text, motivating the need for a new research dataset. We introduce SimSUM, a benchmark dataset of 10,000 simulated patient records that link unstructured clinical notes with structured background variables. Each record simulates a patient encounter in the domain of respiratory diseases and includes tabular data (e.g., symptoms, diagnoses, underlying conditions) generated from a Bayesian network whose structure and parameters are defined by domain experts. A large language model (GPT-4o) is prompted to generate a clinical note describing the encounter, including symptoms and relevant context. These notes are annotated with span-level symptom mentions. We conduct an expert evaluation to assess note quality and run baseline predictive models on both the tabular and textual data. The SimSUM dataset is primarily designed to support research on clinical information extraction in the presence of tabular background variables, which can be linked through domain knowledge to concepts of interest to be extracted from the text -- namely, symptoms in the case of SimSUM. Secondary uses include research on the automation of clinical reasoning over both tabular data and text, causal effect estimation in the presence of tabular and/or textual confounders, and multi-modal synthetic data generation. SimSUM is not intended for training clinical decision support systems or production-grade models, but rather to facilitate reproducible research in a simplified and controlled setting.

  • 3 authors
·
Sep 13, 2024

REVEAL++: Differentiable Phenotypic Grouping for Vision-Language Retinal Modeling of Alzheimer's Disease Risk

The retina offers a noninvasive window into neurodegenerative disease, capturing subtle structural patterns associated with a risk of future cognitive decline. Vision-language alignment frameworks such as REVEAL have shown that pairing retinal fundus images with structured clinical risk narratives improves early prediction of Alzheimer's disease (AD). A key design choice in these approaches is the use of phenotypic grouping, where individuals with similar risk profiles are treated as multi-positive pairs during contrastive learning. However, existing methods operationalize phenotypic similarity as a discrete construct, relying on hard group assignments that impose rigid supervision and decouple group formation from representation learning. We propose a continuous formulation of phenotypic structure within contrastive learning. Rather than assigning samples to fixed clusters, we model inter-subject similarity as a differentiable weighting function derived from intra-modality embedding similarities in both retinal images and risk profiles. These weights define soft multi-positive relationships through a continuous aggregation operator, enabling graded supervision that reflects the spectrum nature of disease risk. We further introduce a soft-target contrastive objective that jointly learns cross-modal alignment and phenotypic structure in an end-to-end manner. Evaluated on UK Biobank retinal imaging data for incident AD prediction, the proposed framework consistently outperforms discrete group-based contrastive learning and standard vision-language baselines. By treating phenotypic similarity as a learnable, continuous signal rather than a fixed grouping rule, our approach provides a principled and robust foundation for population-scale neurodegenerative risk modeling from multi-modal retinal and clinical data.

  • 4 authors
·
Jun 16

DIYHealth Suite: Dataset, Model, and Benchmark for Health Management at Home

Generative AI is reshaping healthcare, yet most existing advances rely on hospital-grade devices, which limits their accessibility and potential for health management outside clinical settings. With the proliferation of portable devices and telemedicine, healthcare is shifting toward home-based Diagnosis-It-Yourself (DIY) care. Despite this promise, several distinctive challenges remain: (i) home-collected data are heterogeneous, exacerbated by the absence of standardized large-scale datasets; (ii) models require adaptation to variable task demands and evolving individual conditions; (iii) the broad spectrum of home care tasks lacks a unified benchmark for systematic evaluation. In this paper, we present DIYHealth Suite, a comprehensive framework designed to address these challenges through a tailored dataset, model, and benchmark. We first curate DIYHealth-900K, a large-scale multimodal dataset capturing diverse real-world home care scenarios. Building on this, we propose DIYHealthGPT, an adaptive foundation model for home-based health management, powered by the novel Hybrid Hyper Low-Rank Adaptation technique. Finally, we establish DIYHealthBench, the first benchmark to evaluate foundation models on home care tasks. Extensive experiments demonstrate that DIYHealthGPT delivers state-of-the-art performance over both general-purpose and medical-specific baselines on 11 home care tasks in both open-QA and closed-QA settings, laying the groundwork for the next generation of personalized health management at home.

  • 12 authors
·
Apr 30

EyeVQA: Benchmarking Ophthalmic Vision-Language Models from Recognition to Spatial Grounding

Vision-language models (VLMs) have shown increasing potential for medical image understanding, yet their capabilities in ophthalmic imaging remain insufficiently characterized. Existing ophthalmic datasets are typically designed for individual diseases or specialized tasks, making it difficult to systematically evaluate whether VLMs can move beyond disease recognition toward comparative reasoning and fine-grained spatial grounding. We introduce EyeVQA, a unified visual question answering benchmark for comprehensive evaluation of ophthalmic VLMs. EyeVQA is constructed from 21 available ophthalmic datasets and contains 20,000 question-answer pairs spanning six disease groups and seven question types: Single-Choice, Multi-Select, Variable-Select, True-False, Ranking, Point Location, and Bounding Box. Gold answers are deterministically derived from source-provided diagnoses, severity grades, clinical findings, segmentation masks, bounding boxes, and anatomical landmarks, enabling reproducible evaluation without relying on model-generated annotations. Notably, 44.5% of the questions require reasoning across multiple images, extending evaluation beyond conventional single-image medical VQA. We benchmark fourteen representative general-purpose, scientific, and medically specialized VLMs under a unified zero-shot protocol. The best-performing model only achieves an overall score of 62.8, while substantial gaps remain in spatial grounding and cross-task generalization. These results highlight the limitations of current VLMs in comprehensive ophthalmic visual understanding and establish EyeVQA as a diagnostic benchmark for developing more reliable and spatially grounded ophthalmic multimodal models. The project page is available at https://github.com/PKUTHM/EyeVQA.

  • 10 authors
·
Sep 25

Multidimensional Rubric-oriented Reward Model Learning via Geometric Projection Reference Constraints

The integration of large language models (LLMs) into medical practice holds transformative potential, yet their real-world clinical utility remains limited by critical alignment challenges: (1) a disconnect between static evaluation benchmarks and dynamic clinical cognitive needs, (2) difficulties in adapting to evolving, multi-source medical standards, and (3) the inability of conventional reward models to capture nuanced, multi-dimensional medical quality criteria. To address these gaps, we propose MR-RML (Multidimensional Rubric-oriented Reward Model Learning) via GPRC (Geometric Projection Reference Constraints), a novel alignment framework that integrates medical standards into a structured "Dimensions-Scenarios-Disciplines" matrix to guide data generation and model optimization. MR-RML introduces three core innovations: (1) a "Dimensions-Scenarios-Disciplines" medical standard system that embeds domain standards into the full training pipeline; (2) an independent multi-dimensional reward model that decomposes evaluation criteria, shifting from real-time rubric-based scoring to internalized reward modeling for improved consistency and cost-efficiency; (3) geometric projection reference constraints that transform medical cognitive logic into mathematical regularization, aligning scoring gradients with clinical reasoning and enabling synthetic data-driven training. Through extensive evaluations on the authoritative medical benchmark Healthbench, our method yields substantial performance gains over the base LLM Qwen-32B (45% on the full subset and 85% on Hard subset, respectively). It achieves a SOTA among open-source LLMs with scores of 62.7 (full subset) and 44.7 (hard subset), while also outperforming the majority of closed-source models.

  • 5 authors
·
Nov 20, 2025

Integrating Clinical Knowledge Graphs and Gradient-Based Neural Systems for Enhanced Melanoma Diagnosis via the 7-Point Checklist

The 7-point checklist (7PCL) is a widely used diagnostic tool in dermoscopy for identifying malignant melanoma by assigning point values to seven specific attributes. However, the traditional 7PCL is limited to distinguishing between malignant melanoma and melanocytic Nevi, and falls short in scenarios where multiple skin diseases with appearances similar to melanoma coexist. To address this limitation, we propose a novel diagnostic framework that integrates a clinical knowledge-based topological graph (CKTG) with a gradient diagnostic strategy featuring a data-driven weighting system (GD-DDW). The CKTG captures both the internal and external relationships among the 7PCL attributes, while the GD-DDW emulates dermatologists' diagnostic processes, prioritizing visual observation before making predictions. Additionally, we introduce a multimodal feature extraction approach leveraging a dual-attention mechanism to enhance feature extraction through cross-modal interaction and unimodal collaboration. This method incorporates meta-information to uncover interactions between clinical data and image features, ensuring more accurate and robust predictions. Our approach, evaluated on the EDRA dataset, achieved an average AUC of 88.6%, demonstrating superior performance in melanoma detection and feature prediction. This integrated system provides data-driven benchmarks for clinicians, significantly enhancing the precision of melanoma diagnosis.

  • 7 authors
·
Jul 23, 2024

Asclepius: An Adaptive Harness for Long-Horizon Clinical Agents

LLM agents are predominantly benchmarked on short, single-task trajectories, yet real deployments run for hours under contention, surfacing a different class of failures. We use the Clinical Environment Simulator (CES), in which an agent manages an entire emergency-department shift under continuous time and resource pressure, as a testbed: long-horizon execution failures manifest measurably in a single rollout under structured, multi-dimensional grading. On CES, current agents reach the correct diagnosis in most cases yet fail to deliver complete and timely critical actions, revealing an execution gap. We attribute this gap to three long-horizon failure modes, each operationalized as a per-trace counter: instruction-adherence drift, treatment incompleteness, and a severity-equity gap in timeliness. We then introduce Asclepius, an adaptive agent scaffolding with a self-evolving harness that rewrites the operating manual between shifts from trace-level feedback, an externalized clinical skills library for high-stakes regimen knowledge, and three isolated subagents that partition per-turn decisions across the patient queue. On held-out batches never observed during harness evolution, Asclepius improves critical-action correctness by 22% (p = 0.024) over a strong baseline agent framework while preserving diagnostic accuracy, with consistent gains across five LLM judges from three model families; on the full ten-batch set, improvements reach 25% on critical actions and 13% on timeliness. The three failure modes form a coupled bottleneck: decisive reductions appear only when all three components act together.

  • 5 authors
·
Sep 10

Teaching LLMs How ICU Physicians Approach Clinical Reasoning Through OMOP-Aligned Retrieval Improves Reasoning Across Clinical Domains

Clinical decision-making relies on identifying relevant patient information to guide diagnosis and treatment, a challenge that is especially difficult in the data-dense and rapidly changing intensive care unit (ICU). Large language models (LLMs) could support this task. However, existing applications and datasets mostly emphasize surface-level retrieval or factual recall rather than the inductive and deductive reasoning clinicians practice to select and reason over decision-relevant evidence. We hypothesized that training LLMs on expert ICU reasoning could yield clinical reasoning skills that generalize beyond critical care. Here we introduce ICU-REACT, a reasoning dataset developed with 19 clinicians through a clinician-in-the-loop framework to teach LLMs to perform information retrieval and context-aware clinical reasoning in the ICU. Using ICU-REACT, we fine-tuned Clin-REACT models spanning 8B-70B parameters and three model families. Across five clinical reasoning benchmarks, Clin-REACT consistently outperformed its backbone models and open-source general-purpose and medical LLMs. Gains extended to different tasks including script concordance tests, and downstream diagnosis and treatment tasks. These findings suggest that expert reasoning supervision in critical care can improve broader clinical reasoning, although prospective evaluation is needed before real-world clinical use.

  • 33 authors
·
Aug 22

GAMMA Challenge:Glaucoma grAding from Multi-Modality imAges

Color fundus photography and Optical Coherence Tomography (OCT) are the two most cost-effective tools for glaucoma screening. Both two modalities of images have prominent biomarkers to indicate glaucoma suspected. Clinically, it is often recommended to take both of the screenings for a more accurate and reliable diagnosis. However, although numerous algorithms are proposed based on fundus images or OCT volumes in computer-aided diagnosis, there are still few methods leveraging both of the modalities for the glaucoma assessment. Inspired by the success of Retinal Fundus Glaucoma Challenge (REFUGE) we held previously, we set up the Glaucoma grAding from Multi-Modality imAges (GAMMA) Challenge to encourage the development of fundus \& OCT-based glaucoma grading. The primary task of the challenge is to grade glaucoma from both the 2D fundus images and 3D OCT scanning volumes. As part of GAMMA, we have publicly released a glaucoma annotated dataset with both 2D fundus color photography and 3D OCT volumes, which is the first multi-modality dataset for glaucoma grading. In addition, an evaluation framework is also established to evaluate the performance of the submitted methods. During the challenge, 1272 results were submitted, and finally, top-10 teams were selected to the final stage. We analysis their results and summarize their methods in the paper. Since all these teams submitted their source code in the challenge, a detailed ablation study is also conducted to verify the effectiveness of the particular modules proposed. We find many of the proposed techniques are practical for the clinical diagnosis of glaucoma. As the first in-depth study of fundus \& OCT multi-modality glaucoma grading, we believe the GAMMA Challenge will be an essential starting point for future research.

  • 29 authors
·
Feb 14, 2022

Enhanced SegNet with Integrated Grad-CAM for Interpretable Retinal Layer Segmentation in OCT Images

Optical Coherence Tomography (OCT) is essential for diagnosing conditions such as glaucoma, diabetic retinopathy, and age-related macular degeneration. Accurate retinal layer segmentation enables quantitative biomarkers critical for clinical decision-making, but manual segmentation is time-consuming and variable, while conventional deep learning models often lack interpretability. This work proposes an improved SegNet-based deep learning framework for automated and interpretable retinal layer segmentation. Architectural innovations, including modified pooling strategies, enhance feature extraction from noisy OCT images, while a hybrid loss function combining categorical cross-entropy and Dice loss improves performance for thin and imbalanced retinal layers. Gradient-weighted Class Activation Mapping (Grad-CAM) is integrated to provide visual explanations, allowing clinical validation of model decisions. Trained and validated on the Duke OCT dataset, the framework achieved 95.77% validation accuracy, a Dice coefficient of 0.9446, and a Jaccard Index (IoU) of 0.8951. Class-wise results confirmed robust performance across most layers, with challenges remaining for thinner boundaries. Grad-CAM visualizations highlighted anatomically relevant regions, aligning segmentation with clinical biomarkers and improving transparency. By combining architectural improvements, a customized hybrid loss, and explainable AI, this study delivers a high-performing SegNet-based framework that bridges the gap between accuracy and interpretability. The approach offers strong potential for standardizing OCT analysis, enhancing diagnostic efficiency, and fostering clinical trust in AI-driven ophthalmic tools.

  • 2 authors
·
Sep 9, 2025

Semixup: In- and Out-of-Manifold Regularization for Deep Semi-Supervised Knee Osteoarthritis Severity Grading from Plain Radiographs

Knee osteoarthritis (OA) is one of the highest disability factors in the world. This musculoskeletal disorder is assessed from clinical symptoms, and typically confirmed via radiographic assessment. This visual assessment done by a radiologist requires experience, and suffers from moderate to high inter-observer variability. The recent literature has shown that deep learning methods can reliably perform the OA severity assessment according to the gold standard Kellgren-Lawrence (KL) grading system. However, these methods require large amounts of labeled data, which are costly to obtain. In this study, we propose the Semixup algorithm, a semi-supervised learning (SSL) approach to leverage unlabeled data. Semixup relies on consistency regularization using in- and out-of-manifold samples, together with interpolated consistency. On an independent test set, our method significantly outperformed other state-of-the-art SSL methods in most cases. Finally, when compared to a well-tuned fully supervised baseline that yielded a balanced accuracy (BA) of 70.9pm0.8% on the test set, Semixup had comparable performance -- BA of 71pm0.8% (p=0.368) while requiring 6 times less labeled data. These results show that our proposed SSL method allows building fully automatic OA severity assessment tools with datasets that are available outside research settings.

  • 4 authors
·
Mar 4, 2020

HealthiVert-GAN: A Novel Framework of Pseudo-Healthy Vertebral Image Synthesis for Interpretable Compression Fracture Grading

Osteoporotic vertebral compression fractures (VCFs) are prevalent in the elderly population, typically assessed on computed tomography (CT) scans by evaluating vertebral height loss. This assessment helps determine the fracture's impact on spinal stability and the need for surgical intervention. However, clinical data indicate that many VCFs exhibit irregular compression, complicating accurate diagnosis. While deep learning methods have shown promise in aiding VCFs screening, they often lack interpretability and sufficient sensitivity, limiting their clinical applicability. To address these challenges, we introduce a novel vertebra synthesis-height loss quantification-VCFs grading framework. Our proposed model, HealthiVert-GAN, utilizes a coarse-to-fine synthesis network designed to generate pseudo-healthy vertebral images that simulate the pre-fracture state of fractured vertebrae. This model integrates three auxiliary modules that leverage the morphology and height information of adjacent healthy vertebrae to ensure anatomical consistency. Additionally, we introduce the Relative Height Loss of Vertebrae (RHLV) as a quantification metric, which divides each vertebra into three sections to measure height loss between pre-fracture and post-fracture states, followed by fracture severity classification using a Support Vector Machine (SVM). Our approach achieves state-of-the-art classification performance on both the Verse2019 dataset and our private dataset, and it provides cross-sectional distribution maps of vertebral height loss. This practical tool enhances diagnostic sensitivity in clinical settings and assisting in surgical decision-making. Our code is available: https://github.com/zhibaishouheilab/HealthiVert-GAN.

  • 6 authors
·
Mar 7, 2025

The Double Dilemma in Multi-Task Radiology Report Generation: A Gradient Dynamics Analysis and Solution

While multi-task learning based automatic radiology report generation (RRG) is widely adopted to ensure clinical consistency, most focus on architectural designs yet remain limited to coarse linear scalarization strategies. These strategies cannot effectively balance the hard constraints of discriminative clinical supervision with the smoothness requirements of report generation. To address these problems, we analyze the failure mechanism of linear scalarization from the perspective of gradient dynamics, utilizing the stochastic differential equation (SDE) framework to characterize it as a "Double Dilemma" of drift term deviation and diffusion term decay. Based on this, we propose a backbone-agnostic optimizer named Conflict-Averse Magnitude-Enhanced Gradient Descent (CAME-Grad). Through conflict-averse direction rectification and magnitude-enhanced energy injection, the algorithm not only ensures geometric validity, but also avoids local optimal solutions. Then, the adaptive gradient fusion mechanism is used to establish a dynamic balance between the theoretical optimal direction and the task-specific inductive bias. Experiments show that as a universal plug-and-play optimizer, CAME-Grad brings substantial and consistent improvements across eight diverse RRG methods, elevating overall clinical efficacy performance by an average of 2.3% on MIMIC-CXR and 1.9% on IU X-Ray. Our code is available at https://github.com/vpsg-research/CAME-Grad.

  • 4 authors
·
May 21

Scaling Clinical Judgment to Evaluate Medical AI

Blinded physician evaluation has been considered by many to be the gold standard for assessing clinical reasoning in large language models (LLMs). This is difficult to scale; thus, prior studies typically rely on small physician panels, often from a single institution or specialty, which both limits the scientific questions investigated and makes it unclear whether findings would be reproduced with a different set of evaluators. To more rigorously and scalably study clinical reasoning in AI models, here we introduce PrecepTron, an LLM fine-tuned for physician-level evaluation of open-ended responses. PrecepTron was trained using low-rank adaptation (LoRA) of a 32-billion-parameter model on a small number of physician examples. We also release GRAND-ROUNDS, a new large-scale physician-annotated benchmark of 9,217 scores by 11 physicians across seven studies. We show that frontier LLMs in typical "LLM-as-a-judge" approaches often disagree with physicians and with each other, but fine-tuning PrecepTron on a small number of cases enables physician-level consistent scoring across tasks. We use PrecepTron to reproduce headline findings from five influential studies assessing LLMs for clinical care in JAMA, Science, and Nature Medicine without new human grading. Using PrecepTron, we then pose new questions about how LLMs reason in medicine that would have been infeasible with human grading alone, including measuring the diagnostic accuracy of frontier LLMs when clinical cases are provided piecemeal, even token by token. Together, PrecepTron and GRAND-ROUNDS provide a foundation for reproducible, large-scale study of how LLMs reason in medicine. All code, data, and labels are made freely available for researchers.

  • 17 authors
·
Sep 10

FleXray: Universal Clinical X-ray Segmentation

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

  • 5 authors
·
Sep 21

Colon-X: Advancing Intelligent Colonoscopy from Multimodal Understanding to Clinical Reasoning

In this study, we present Colon-X, an open initiative aimed at advancing multimodal intelligence in colonoscopy. We begin by constructing ColonVQA, the most comprehensive multimodal dataset ever built for colonoscopy, featuring over 1.1M+ visual question answering entries across 76 clinical findings and 18 multimodal tasks. Beyond serving as a community-wide data foundation, we further investigate a critical yet underexplored transition in colonoscopy - evolving from multimodal understanding to clinical reasoning: (a) To capture the current landscape of multimodal understanding behaviors, we systematically assess the generalizability of 22 multimodal large language models and examine their reliability under human-induced perturbations. The results reveal that clinical outputs from leading MLLMs remain far from robust and trustworthy. (b) To narrow this gap, we further explore reasoning-centric intelligence tailored for colonoscopy. Specifically, we curate ColonReason, a clinically grounded reasoning dataset annotated through a multi-expert debating pipeline, and develop ColonR1, the first R1-styled model incorporating task-adaptive rewarding and gradient-stable optimization techniques. Under data-scarce conditions, our ColonR1 achieves 56.61% overall accuracy, outperforming supervised fine-tuning by 25.22%, and sets a new reasoning-enabled baseline for multimodal colonoscopy analysis. All data and model resources are publicly available at https://github.com/ai4colonoscopy/Colon-X.

Multicentric thrombus segmentation using an attention-based recurrent network with gradual modality dropout

Detecting and delineating tiny targets in 3D brain scans is a central yet under-addressed challenge in medical imaging.In ischemic stroke, for instance, the culprit thrombus is small, low-contrast, and variably expressed across modalities(e.g., susceptibility-weighted T2 blooming, diffusion restriction on DWI/ADC), while real-world multi-center dataintroduce domain shifts, anisotropy, and frequent missing sequences. We introduce a methodology that couples an attention-based recurrent segmentation network (UpAttLLSTM), a training schedule that progressively increases the difficulty of hetero-modal learning, with gradual modality dropout, UpAttLLSTM aggregates context across slices via recurrent units (2.5D) and uses attention gates to fuse complementary cues across available sequences, making it robust to anisotropy and class imbalance. Gradual modality dropout systematically simulates site heterogeneity,noise, and missing modalities during training, acting as both augmentation and regularization to improve multi-center generalization. On a monocentric cohort, our approach detects thrombi in >90% of cases with a Dice score of 0.65. In a multi-center setting with missing modalities, it achieves-80% detection with a Dice score around 0.35. Beyond stroke, the proposed methodology directly transfers to other small-lesion tasks in 3D medical imaging where targets are scarce, subtle, and modality-dependent

  • 4 authors
·
Mar 31

Retrieval-Augmented Multimodal Language Model with Heterogeneous Evidence Integration for Clinical Prognosis

Clinical prognosis requires integrating structured measurements, physiological waveforms, longitudinal history, and population context. We introduce PRISM (Population-Retrieved Inference for Structured Multimodal Prognosis), a multimodal language model that combines per-feature numerical tokenization, recency-weighted aggregation of longitudinal ECGs, and a dual-modality population memory bank. Retrieval operates in representation space: the model receives mean-pooled embeddings of similar training-cohort encounters, while no individual retrieved record enters the prompt. On the 1,443-task MDS-ED benchmark, PRISM achieves AUROCs of 86.2% for diagnosis, 93.1% for deterioration, 91.8% for ICU admission, and 92.8% for mortality. These results use a 96-hour pre-arrival window unavailable to reported baselines. With benchmark-window inputs only, PRISM reaches 0.8895 AUROC, compared with 0.8937 for UniPACT and 0.8889 for MDS-ED. A matched-input compact fusion model using the same five evidence streams and frozen encoders reaches 0.7652 AUROC, versus 0.9092 for PRISM. Replacing numerical EHR encoding with text serialization reduces AUROC by 3.66 points; removing pre-arrival history reduces it by 1.97 points; and zeroing retrieval reduces it by 0.99 points. Genuine retrieval outperforms random-neighbor retrieval by 0.97 macro-average points, although a paired task-level sign test does not establish a uniform advantage (p=0.067). On the external MC-MED cohort, supervised fine-tuning reaches 0.8611 AUROC, compared with 0.8227 for locally trained gradient boosting and 0.7841 for source-only PRISM. These results support structure-aware multimodal integration and supervised external adaptation.

  • 5 authors
·
Oct 8

Weakly Supervised Pneumonia Localization from Chest X-Rays Using Deep Neural Network and Grad-CAM Explanations

Chest X-ray imaging is commonly used to diagnose pneumonia, but accurately localizing the pneumonia-affected regions typically requires detailed pixel-level annotations, which are costly and time consuming to obtain. To address this limitation, this study proposes a weakly supervised deep learning framework for pneumonia classification and localization using Gradient-weighted Class Activation Mapping (Grad-CAM). Instead of relying on costly pixel-level annotations, the proposed method utilizes image-level labels to generate clinically meaningful heatmaps that highlight pneumonia-affected regions. Furthermore, we evaluate seven pre-trained deep learning models, including a Vision Transformer, under identical training conditions, using focal loss and patient-wise splits to prevent data leakage. Experimental results suggest that all models achieved high classification accuracy (96--98\%), with ResNet-18 and EfficientNet-B0 showing the best overall performance and MobileNet-V3 providing an efficient lightweight alternative. Grad-CAM heatmap visualizations confirm that the proposed methods focus on clinically relevant lung regions, supporting the use of explainable AI for radiological diagnostics. Overall, this work highlights the potential of weakly supervised, explainable models that enhance transparency and clinical trust in AI-assisted pneumonia screening.

  • 2 authors
·
Nov 1, 2025

EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical Reasoning

Endoscopic diagnosis unfolds over native video, where a single positive finding during traversal of the gastrointestinal tract sets off a multi-minute chain of reasoning over location, morphology, severity and intervention. Existing endoscopy multimodal benchmarks test only static images or single-disease videos, which miss the temporal and clinical reasoning that real-world reporting demands. We introduce EndoSCOP-V, a video-grounded multi-turn evaluation framework for structured endoscopy reporting and clinical reasoning. It contains 1,307 real-world endoscopy and colonoscopy videos (63.2 h; 97% 1080p) averaging about 174 s. Its 20,274 question-answer turns are instantiated deterministically from clinician-filled structured endoscopy-reporting EHRs, so no per-case annotation is synthetic or LLM-rephrased. They come from 1,033 clinician-reviewed templates, about 18 per disease, that span a clinically aligned 9-task x 30-sub-task reporting taxonomy over 54 World Endoscopy Organization (WEO) MST 3.0 diseases. 22% of procedures carry co-existing pathologies, up to six per case. A Markovian context-pruned oracle-forcing protocol evaluates the dialogue turn by turn, injecting the gold answer before each subsequent turn so that per-turn reasoning is isolated from cascading dialogue errors. A panel of 15 board-certified endoscopists sets a 78% strict-accuracy baseline on 1,500 questions. Across 14 open-weight LMMs, the best 27B-class model reaches 59.8% strict accuracy, falling to 53.4% once format-trivial disease-rejection items are excluded. On a between-subjects spot-check, the best of 3 frontier proprietary models trails the clinician panel by 23 pp on strict NDR accuracy. Sub-task analysis reveals consistent gaps in quantitative measurement, multi-variable grading and intervention reasoning on long-horizon video. Data: Hugging Face (EndoSCOP-V). Code: GitHub (abhi25t/EndoSCOP-V).

  • 18 authors
·
Nov 6

Merlin: A Vision Language Foundation Model for 3D Computed Tomography

Over 85 million computed tomography (CT) scans are performed annually in the US, of which approximately one quarter focus on the abdomen. Given the current radiologist shortage, there is a large impetus to use artificial intelligence to alleviate the burden of interpreting these complex imaging studies. Prior state-of-the-art approaches for automated medical image interpretation leverage vision language models (VLMs). However, current medical VLMs are generally limited to 2D images and short reports, and do not leverage electronic health record (EHR) data for supervision. We introduce Merlin - a 3D VLM that we train using paired CT scans (6+ million images from 15,331 CTs), EHR diagnosis codes (1.8+ million codes), and radiology reports (6+ million tokens). We evaluate Merlin on 6 task types and 752 individual tasks. The non-adapted (off-the-shelf) tasks include zero-shot findings classification (31 findings), phenotype classification (692 phenotypes), and zero-shot cross-modal retrieval (image to findings and image to impressions), while model adapted tasks include 5-year disease prediction (6 diseases), radiology report generation, and 3D semantic segmentation (20 organs). We perform internal validation on a test set of 5,137 CTs, and external validation on 7,000 clinical CTs and on two public CT datasets (VerSe, TotalSegmentator). Beyond these clinically-relevant evaluations, we assess the efficacy of various network architectures and training strategies to depict that Merlin has favorable performance to existing task-specific baselines. We derive data scaling laws to empirically assess training data needs for requisite downstream task performance. Furthermore, unlike conventional VLMs that require hundreds of GPUs for training, we perform all training on a single GPU.

  • 31 authors
·
Jun 10, 2024

The Anatomy of a Personal Health Agent

Health is a fundamental pillar of human wellness, and the rapid advancements in large language models (LLMs) have driven the development of a new generation of health agents. However, the application of health agents to fulfill the diverse needs of individuals in daily non-clinical settings is underexplored. In this work, we aim to build a comprehensive personal health agent that is able to reason about multimodal data from everyday consumer wellness devices and common personal health records, and provide personalized health recommendations. To understand end-users' needs when interacting with such an assistant, we conducted an in-depth analysis of web search and health forum queries, alongside qualitative insights from users and health experts gathered through a user-centered design process. Based on these findings, we identified three major categories of consumer health needs, each of which is supported by a specialist sub-agent: (1) a data science agent that analyzes personal time-series wearable and health record data, (2) a health domain expert agent that integrates users' health and contextual data to generate accurate, personalized insights, and (3) a health coach agent that synthesizes data insights, guiding users using a specified psychological strategy and tracking users' progress. Furthermore, we propose and develop the Personal Health Agent (PHA), a multi-agent framework that enables dynamic, personalized interactions to address individual health needs. To evaluate each sub-agent and the multi-agent system, we conducted automated and human evaluations across 10 benchmark tasks, involving more than 7,000 annotations and 1,100 hours of effort from health experts and end-users. Our work represents the most comprehensive evaluation of a health agent to date and establishes a strong foundation towards the futuristic vision of a personal health agent accessible to everyone.

  • 38 authors
·
Aug 27, 2025

Efficient Feature Extraction Using Light-Weight CNN Attention-Based Deep Learning Architectures for Ultrasound Fetal Plane Classification

Ultrasound fetal imaging is beneficial to support prenatal development because it is affordable and non-intrusive. Nevertheless, fetal plane classification (FPC) remains challenging and time-consuming for obstetricians since it depends on nuanced clinical aspects, which increases the difficulty in identifying relevant features of the fetal anatomy. Thus, to assist with its accurate feature extraction, a lightweight artificial intelligence architecture leveraging convolutional neural networks and attention mechanisms is proposed to classify the largest benchmark ultrasound dataset. The approach fine-tunes from lightweight EfficientNet feature extraction backbones pre-trained on the ImageNet1k. to classify key fetal planes such as the brain, femur, thorax, cervix, and abdomen. Our methodology incorporates the attention mechanism to refine features and 3-layer perceptrons for classification, achieving superior performance with the highest Top-1 accuracy of 96.25%, Top-2 accuracy of 99.80% and F1-Score of 0.9576. Importantly, the model has 40x fewer trainable parameters than existing benchmark ensemble or transformer pipelines, facilitating easy deployment on edge devices to help clinical practitioners with real-time FPC. The findings are also interpreted using GradCAM to carry out clinical correlation to aid doctors with diagnostics and improve treatment plans for expectant mothers.

  • 4 authors
·
Oct 22, 2024

Explainable Multi-Modal Deep Learning for Automatic Detection of Lung Diseases from Respiratory Audio Signals

Respiratory diseases remain major global health challenges, and traditional auscultation is often limited by subjectivity, environmental noise, and inter-clinician variability. This study presents an explainable multimodal deep learning framework for automatic lung-disease detection using respiratory audio signals. The proposed system integrates two complementary representations: a spectral-temporal encoder based on a CNN-BiLSTM Attention architecture, and a handcrafted acoustic-feature encoder capturing physiologically meaningful descriptors such as MFCCs, spectral centroid, spectral bandwidth, and zero-crossing rate. These branches are combined through late-stage fusion to leverage both data-driven learning and domain-informed acoustic cues. The model is trained and evaluated on the Asthma Detection Dataset Version 2 using rigorous preprocessing, including resampling, normalization, noise filtering, data augmentation, and patient-level stratified partitioning. The study achieved strong generalization with 91.21% accuracy, 0.899 macro F1-score, and 0.9866 macro ROC-AUC, outperforming all ablated variants. An ablation study confirms the importance of temporal modeling, attention mechanisms, and multimodal fusion. The framework incorporates Grad-CAM, Integrated Gradients, and SHAP, generating interpretable spectral, temporal, and feature-level explanations aligned with known acoustic biomarkers to build clinical transparency. The findings demonstrate the framework's potential for telemedicine, point-of-care diagnostics, and real-world respiratory screening.

  • 4 authors
·
Nov 29, 2025

Can-SAVE: Deploying Low-Cost and Population-Scale Cancer Screening via Survival Analysis Variables and EHR

Conventional medical cancer screening methods are costly, labor-intensive, and extremely difficult to scale. Although AI can improve cancer detection, most systems rely on complex or specialized medical data, making them impractical for large-scale screening. We introduce Can-SAVE, a lightweight AI system that ranks population-wide cancer risks solely based on medical history events. By integrating survival model outputs into a gradient-boosting framework, our approach detects subtle, long-term patient risk patterns - often well before clinical symptoms manifest. Can-SAVE was rigorously evaluated on a real-world dataset of 2.5 million adults spanning five Russian regions, marking the study as one of the largest and most comprehensive deployments of AI-driven cancer risk assessment. In a retrospective oncologist-supervised study over 1.9M patients, Can-SAVE achieves a 4-10x higher detection rate at identical screening volumes and an Average Precision (AP) of 0.228 vs. 0.193 for the best baseline (LoRA-tuned Qwen3-Embeddings via DeepSeek-R1 summarization). In a year-long prospective pilot (426K patients), our method almost doubled the cancer detection rate (+91%) and increased population coverage by 36% over the national screening protocol. The system demonstrates practical scalability: a city-wide population of 1 million patients can be processed in under three hours using standard hardware, enabling seamless clinical integration. This work proves that Can-SAVE achieves nationally significant cancer detection improvements while adhering to real-world public healthcare constraints, offering immediate clinical utility and a replicable framework for population-wide screening. Code for training and feature engineering is available at https://github.com/sb-ai-lab/Can-SAVE.

ai-lab sb-ai-lab
·
Sep 26, 2023

Molecular-driven Foundation Model for Oncologic Pathology

Foundation models are reshaping computational pathology by enabling transfer learning, where models pre-trained on vast datasets can be adapted for downstream diagnostic, prognostic, and therapeutic response tasks. Despite these advances, foundation models are still limited in their ability to encode the entire gigapixel whole-slide images without additional training and often lack complementary multimodal data. Here, we introduce Threads, a slide-level foundation model capable of generating universal representations of whole-slide images of any size. Threads was pre-trained using a multimodal learning approach on a diverse cohort of 47,171 hematoxylin and eosin (H&E)-stained tissue sections, paired with corresponding genomic and transcriptomic profiles - the largest such paired dataset to be used for foundation model development to date. This unique training paradigm enables Threads to capture the tissue's underlying molecular composition, yielding powerful representations applicable to a wide array of downstream tasks. In extensive benchmarking across 54 oncology tasks, including clinical subtyping, grading, mutation prediction, immunohistochemistry status determination, treatment response prediction, and survival prediction, Threads outperformed all baselines while demonstrating remarkable generalizability and label efficiency. It is particularly well suited for predicting rare events, further emphasizing its clinical utility. We intend to make the model publicly available for the broader community.

  • 18 authors
·
Jan 27, 2025

MedPRMBench: A Fine-grained Benchmark for Process Reward Models in Medical Reasoning

Process-Level Reward Models (PRMs) are essential for guiding complex reasoning in large language models, yet existing PRM benchmarks cover only general domains such as mathematics, failing to address medical reasoning -- which is uniquely characterized by safety criticality, knowledge intensity, and diverse error patterns. Without a reliable medical PRM evaluation framework, we cannot quantify models' error detection capabilities in clinical reasoning, leaving their safety in real-world healthcare applications unverified. We propose MedPRMBench, the first process-level reward model benchmark for the medical domain. Built through a three-phase pipeline based on Clinical Reasoning Blueprints (CRBs), MedPRMBench systematically generates high-quality evaluation data from seven medical QA sources, covering 14 fine-grained error types across three categories (Simplicity, Soundness, and Sensitivity) with the first 4-level severity grading system to quantify clinical impact. The benchmark comprises 6{,}500 questions with 13{,}000 reasoning chains and 113{,}910 step-level labels, plus 6{,}879 questions for training. Our medical PRM baseline achieves an 87.1\% overall PRMScore -- substantially surpassing all baselines -- and serves as a plug-and-play verifier that improves downstream medical QA accuracy by 3.2--6.7 percentage points. Systematic evaluation spanning proprietary frontier models, open-source reasoning models, and medical-specialized models reveals critical weaknesses in current models' medical reasoning error detection capabilities, providing clear directions for future PRM improvement.

  • 8 authors
·
Apr 18